Hooft P, van de Voorde H
Katholieke Universiteit Leuven, Laboratory of Forensic Medicine, Belgium.
Z Rechtsmed. 1990;103(8):581-6. doi: 10.1007/BF01261422.
The sensitivity and specificity of a zinc spot test for the detection of semen were compared with those of an acid phosphatase detection method. As screening techniques both tests were found to be very sensitive, but the zinc test was more specific and was more reliable in older and especially in deteriorated specimens. It is concluded that the zinc spot test deserves at least the same place as the acid phosphatase test in the primary investigation of suspected semen stains and might well be the test of choice in older and poorly preserved stains.
将用于检测精液的锌斑试验的灵敏度和特异性与酸性磷酸酶检测方法的灵敏度和特异性进行了比较。作为筛查技术,发现这两种试验都非常灵敏,但锌试验更具特异性,在陈旧标本尤其是变质标本中更可靠。得出的结论是,在对疑似精液污渍的初步调查中,锌斑试验至少应与酸性磷酸酶试验处于同等地位,并且很可能是陈旧和保存不佳污渍的首选检测方法。