Suppr超能文献

经心脏传导电击武器(泰瑟枪)探头部署:发生率及结果

Transcardiac conducted electrical weapon (TASER) probe deployments: incidence and outcomes.

作者信息

Bozeman William P, Teacher Eric, Winslow James E

机构信息

Department of Emergency Medicine, Wake Forest University School of Medicine, Winston Salem, North Carolina 27106, USA.

出版信息

J Emerg Med. 2012 Dec;43(6):970-5. doi: 10.1016/j.jemermed.2012.03.022. Epub 2012 Jun 5.

Abstract

BACKGROUND

TASER (TASER International, Scottsdale, AZ) conducted electrical weapons (CEWs) are commonly used by law enforcement officers. Although animal studies have suggested that transcardiac CEW discharges may produce direct cardiac effects, this has not been demonstrated in human studies.

OBJECTIVES

This study sought to determine the incidence and outcomes of transcardiac CEW probe impact locations in a large series of actual CEW deployments.

METHODS

A multi-center database of consecutive CEW uses by law enforcement officers was retrospectively reviewed. Case report forms were independently reviewed by three investigators to identify cases with paired probe configurations potentially producing a transcardiac discharge vector. Descriptive analysis was performed and inter-rater reliability was assessed.

RESULTS

Among 1201 total CEW uses, 813 included probe deployments and 178 cases had paired anterior probe impacts potentially capable of producing a transcardiac discharge vector. This represents 14.8% of all CEW uses (95% confidence interval [CI] 12.9-16.9%) and 21.9% of CEW uses in probe mode (95% CI 19.1-24.9%). Inter-rater agreement was very good, with kappa = 0.82. There were no immediate deaths in any cases (97.5% CI 0.0-0.3%) to suggest a cardiac dysrhythmia, including those with transcardiac discharge vector.

CONCLUSION

CEW deployments with probe impact configurations capable of producing a transcardiac discharge occur in a minority of cases in field use conditions. None of these cases, transcardiac or otherwise, produced immediately fatal dysrhythmias. These data support the overall safety of CEWs and provide a benchmark estimate of the likelihood of transcardiac discharge vectors occurring in field use of CEWs.

摘要

背景

泰瑟枪(泰瑟国际公司,亚利桑那州斯科茨代尔)传导式电子武器(CEW)被执法人员广泛使用。尽管动物研究表明经心脏的CEW放电可能产生直接的心脏效应,但这在人体研究中尚未得到证实。

目的

本研究旨在确定在大量实际CEW使用案例中经心脏CEW探针撞击位置的发生率及结果。

方法

对执法人员连续使用CEW的多中心数据库进行回顾性分析。三名研究人员独立审查病例报告表,以识别具有可能产生经心脏放电视角的成对探针配置的案例。进行描述性分析并评估评分者间的可靠性。

结果

在总共1201次CEW使用中,813次涉及探针部署,178例有成对的前位探针撞击,有可能产生经心脏放电视角。这占所有CEW使用的14.8%(95%置信区间[CI] 12.9 - 16.9%),占探针模式下CEW使用的21.9%(95% CI 19.1 - 24.9%)。评分者间的一致性非常好,kappa = 0.82。所有案例中均无即刻死亡(97.5% CI 0.0 - 0.3%)提示心律失常,包括那些具有经心脏放电视角的案例。

结论

在现场使用情况下,少数案例中会出现具有能够产生经心脏放电视角的探针撞击配置的CEW部署。这些案例,无论是经心脏的还是其他情况,均未产生即刻致命的心律失常。这些数据支持了CEW的总体安全性,并为CEW现场使用中经心脏放电视角出现的可能性提供了一个基准估计。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验