Abstract

INTRODUCTION

Posterior Condylar Offset is an area of interest in knee arthroplasty research and clinical outcome. The aim of the study is to define a quantifiable Posterior Condylar Offset Ratio, a normal value for this ratio and to confirm its reproducibility on pre-operative radiographs.

METHOD

We propose a new Posterior Condylar Offset Ratio which is defined as the maximal thickness of the posterior condyle projecting posteriorly to a straight line drawn as the extension of the posterior femoral shaft cortex, divided by the maximal thickness of the posterior condyle projecting posterior to a straight line drawn as the extension of the anterior femoral shaft cortex on a true lateral radiograph of the distal quarter of the femur. We have measured this on 100 true lateral radiographs (50 females, 50 males, and mean age 65 years).

RESULTS

The mean ratio was 0.44 (SD 0.02) and was shown to have good reproducibility (intra-observer error 0.899 and inter-observer error 0.882. The ratio was also very consistent between male and female patients (0.44 (SD 0.02) for the males and 0.45 (SD 0.02) for the females). Adjusting the ratio for reported posterior condyle articular cartilage thickness increased the ratio to 0.47 (SD 0.02).

CONCLUSION

We suggest our Posterior Condylar Offset Ratio is a useful tool to aid further research in this area of knee arthroplasty and propose a normal value of 0.44 on radiographs and 0.47 on post-operative knee arthroplasty radiographs.

摘要

引言

后髁偏移是膝关节置换研究和临床结果中一个备受关注的领域。本研究的目的是定义一个可量化的后髁偏移比率,确定该比率的正常值,并在术前X线片上证实其可重复性。

方法

我们提出了一种新的后髁偏移比率,其定义为在股骨远端四分之一的真正侧位X线片上,后髁向后突出到作为股骨干后侧皮质延伸线的直线后的最大厚度,除以向后突出到作为股骨干前侧皮质延伸线的直线后的后髁最大厚度。我们在100张真正侧位X线片上进行了测量(50名女性,50名男性,平均年龄65岁)。

结果

平均比率为0.44(标准差0.02),并显示出良好的可重复性(观察者内误差0.899,观察者间误差0.882)。该比率在男性和女性患者之间也非常一致(男性为0.44(标准差0.02),女性为0.45(标准差0.02))。根据报道的后髁关节软骨厚度调整该比率后,比率增加到0.47(标准差0.02)。

结论

我们认为我们的后髁偏移比率是有助于膝关节置换这一领域进一步研究的有用工具,并提出X线片上的正常值为0.44,膝关节置换术后X线片上的正常值为0.47。