The aim of this retrospective study was to identify factors affecting myopic shift from predicted values of refraction after sulcus fixation of foldable acrylic intraocular lenses (IOLs).
A total of 91 eyes from 91 consecutive patients, each of whom underwent primary implantation of sulcus-fixated foldable acrylic IOLs, were assessed. AcrySof MA60BM and Sensar AR40e multi-piece IOLs, and AcrySof SA60AT and BioVue single-piece IOLs were implanted. The type of IOL and axial length (AL) were analysed to identify differences in the spherical equivalent between the predicted refraction values obtained using the SRK/T formula and the manifested refraction values.
The mean myopic shift from the predicted refraction calculated using the SRK/T formula was -1.04 dioptres (D) ±0.85 SD with sulcus fixation of the foldable acrylic IOLs. The type of IOL (multi-piece vs single-piece) did not affect the degree of myopic shift (p=0.100, independent t-test). However, as the AL increased, the myopic shift decreased (p=0.033, r=0.223, Pearson's correlation).
The myopic shift from the predicted refraction differed following sulcus fixation of foldable acrylic IOLs based on the AL, and therefore surgeons should take the AL into account when they determine the IOL power for sulcus fixation procedures.
本回顾性研究旨在确定影响折叠式丙烯酸人工晶状体(IOL)巩膜固定术后预测屈光度近视漂移的因素。
共评估了 91 例 91 只连续眼,每只眼均行巩膜固定折叠式丙烯酸 IOL 一期植入术。植入了 AcrySof MA60BM 和 Sensar AR40e 多件式 IOL 以及 AcrySof SA60AT 和 BioVue 单件式 IOL。分析了 IOL 类型和眼轴(AL),以确定 SRK/T 公式得出的预测屈光度与实际屈光度之间的球镜等效值的差异。
折叠式丙烯酸 IOL 巩膜固定术后,使用 SRK/T 公式计算的预测屈光度平均近视漂移为-1.04 屈光度(D)±0.85 标准差。IOL 类型(多件式与单件式)不会影响近视漂移程度(p=0.100,独立 t 检验)。然而,随着 AL 的增加,近视漂移减少(p=0.033,r=0.223,皮尔逊相关)。
折叠式丙烯酸 IOL 巩膜固定术后,预测屈光度的近视漂移程度因 AL 而异,因此外科医生在确定巩膜固定术的 IOL 度数时应考虑 AL。