Suppr超能文献

猫冠状动脉灌注压的逐渐降低:血流跨壁分布的变化

Gradual reduction of coronary perfusion pressure in cats: changes in transmural distribution of blood flow.

作者信息

Birkeland S, Hexeberg E, Matre K, Kvitting P, Westby J, Lekven J, Grong K

机构信息

Department of Surgery, University of Bergen, Haukeland Hospital, Norway.

出版信息

Scand J Clin Lab Invest. 1990 Nov;50(7):787-96. doi: 10.1080/00365519009091074.

Abstract

We evaluated a model for regional myocardial hypoperfusion in cats with an extracorporeal shunt line to the left main coronary artery, and investigated the effects of reduced coronary perfusion pressure on the transmural distribution of left ventricular blood flow measured with radioactive microspheres. Shunt establishment did not alter cardiac function, myocardial tissue blood flow, or its transmural distribution. An artificial shunt stenosis, which clearly reduced coronary perfusion pressure without changing cardiac function, caused reduced endocardial blood flow, slight flow reduction in mid-myocardium, and no flow change in the epicardium. When a severe stenosis was applied, causing increased end-diastolic pressure and reduced shunt flow, endocardial and mid-myocardial flow further decreased whereas epicardial blood flow remained essentially unchanged. These results demonstrate a transmural profile of the coronary autoregulation capacity.

摘要

我们评估了一种用于猫的区域性心肌灌注不足的模型,该模型通过体外分流管连接至左主冠状动脉,并研究了冠状动脉灌注压降低对用放射性微球测量的左心室血流跨壁分布的影响。建立分流并未改变心脏功能、心肌组织血流或其跨壁分布。人工分流狭窄在不改变心脏功能的情况下明显降低了冠状动脉灌注压,导致心内膜血流减少,心肌中层血流略有减少,而心外膜血流无变化。当应用严重狭窄导致舒张末期压力升高和分流流量减少时,心内膜和心肌中层血流进一步减少,而心外膜血流基本保持不变。这些结果证明了冠状动脉自动调节能力的跨壁特征。