使用电极放置组合对眼内肿瘤进行电化学溶解。

Electrochemical lysis of an intraocular tumour using a combination of electrode placements.

作者信息

Belyy Y, Tereshchenko A, Shatskih A

机构信息

The Interdisciplinary Scientific and Technological Complex (ISTC) Eye Microsurgery, Kaluga, Russia.

出版信息

Ecancermedicalscience. 2012;6:272. doi: 10.3332/ecancer.2012.272. Epub 2012 Oct 8.

Abstract

UNLABELLED

The objective of this experimental study was to develop a new combination technique for electrode placement and the histomorphological evaluation of its effectiveness for the electrochemical lysis of large intraocular tumours.

MATERIALS AND METHODS

The ECL was conducted on two freshly enucleated eyes containing large tumours, with maximal prominence of 11 and 12 mm and maximal base diameter of 16 and 19 mm, respectively. The ECL was carried out using an ECU-300 (Soring, Germany) apparatus generating an electrochemical charge of 30-35 K. In the course of the ECL procedure we used a new original combination technique of electrode placement, i.e., the anode was a surface electrode and the cathode was an intrastromal electrode. The anode had an original design.

RESULTS

A greyscale B-scan performed after the ECL completion showed decreased echogenicity and heterogeneity of the echo-structure of the tumour. According to the bioimpedancemetry data, the average duration of the ECL session was from 20 to 30 minutes depending on the tumour size. The results of pathomorphological examination performed after the ECL on two freshly enucleated eyes appeared to be similar. Thus, in both cases after lysis the eyeball did not change its size or shape. In both cases the tumour originated from the choroid plexus and showed subtotal necrosis. There was a pronounced boundary between the intact and electrochemically damaged tumour regions which attests to the local effect of the ECL restricted to the electrode placement area only.

DISCUSSION

The growing interest in the ECL procedure is due not only to its availability and low cost but mainly to its real clinical effect demonstrated in numerous publications. The absence of a developed ECL technology for the treatment of intraocular tumors, and, hence, reports on its clinical effectiveness, gave us the impetus to conduct this study. The proposed ECL method is promising and can be considered as optional for the organ-sparing treatment of large-sized intraocular tumours. Further optimization of the ECL parameters, as well as the development of sets of surface and intrastromal electrodes for different types of tumours, is required.

摘要

未标注

本实验研究的目的是开发一种新的电极放置组合技术,并对其用于眼内大肿瘤电化学溶解的有效性进行组织形态学评估。

材料与方法

在两只刚摘除的、含有大肿瘤的眼睛上进行电化学溶解(ECL),肿瘤最大突出度分别为11毫米和12毫米,最大基底直径分别为16毫米和19毫米。使用产生30 - 35K电化学电荷的ECU - 300(德国索林公司)设备进行ECL。在ECL过程中,我们使用了一种新的原创电极放置组合技术,即阳极是表面电极,阴极是基质内电极。阳极有原创设计。

结果

ECL完成后进行的灰度B超扫描显示肿瘤回声结构的回声性降低且不均匀。根据生物阻抗测量数据,ECL疗程的平均持续时间为20至30分钟,具体取决于肿瘤大小。对两只刚摘除的眼睛进行ECL后进行的病理形态学检查结果相似。因此,在两种情况下,溶解后眼球大小和形状均未改变。在两种情况下,肿瘤均起源于脉络丛并显示出部分坏死。完整区域与电化学损伤的肿瘤区域之间有明显界限,这证明ECL的局部效应仅局限于电极放置区域。

讨论

对ECL程序的兴趣日益增加,不仅因为其可用性和低成本,主要还因为众多出版物中展示的实际临床效果。缺乏用于治疗眼内肿瘤的成熟ECL技术,因此也缺乏关于其临床有效性的报告,这促使我们开展本研究。所提出的ECL方法很有前景,可被视为大尺寸眼内肿瘤保留器官治疗的一种选择。需要进一步优化ECL参数,以及开发针对不同类型肿瘤的表面和基质内电极组。