在C-2场反向配置等离子体中,使用氘巴耳末-α诊断方法测量中性密度分布。

Measurements of neutral density profiles using a deuterium Balmer-alpha diagnostic in the C-2 FRC plasma.

作者信息

Gupta Deepak K, Deng B H, Knapp K, Sun X, Thompson M C

机构信息

Tri Alpha Energy, Rancho Santa Margarita, California 92688, USA.

出版信息

Rev Sci Instrum. 2012 Oct;83(10):10D534. doi: 10.1063/1.4742141.

Abstract

In C-2 field-reversed configuration (FRC) device, low neutral density outside the FRC separatrix is required to minimize the charge exchange loss of fast particles. Titanium gettering is used in C-2 to reduce the wall recycling and keep the neutral density low in plasma edge. The measurements of neutral density radial profile are desirable to understand the plasma recycling and the effects of titanium gettering. These measurements are also needed to study the interaction of neutral beams with FRC plasma and confinement of fast ions. Diagnostic based on absolute deuterium Balmer-alpha (D-alpha) radiation measurements is developed and deployed on C-2 device to measure the radial profile of neutral density. Simultaneous measurements of electron density and temperature are done using CO(2) interferometer, Thomson scattering, and triple probes diagnostics along with absolute D-alpha radiation. Abel inversion was performed to get the time dependent radial profile of the local D-alpha emission density. Neutral density profiles are obtained under different machine conditions of titanium deposition.

摘要

在C - 2场反向配置(FRC)装置中,需要在FRC磁分界面之外保持低中性密度,以尽量减少快粒子的电荷交换损失。C - 2装置中采用钛吸气法来减少壁面再循环,并使等离子体边缘的中性密度保持在较低水平。测量中性密度径向分布有助于了解等离子体再循环以及钛吸气的效果。研究中性束与FRC等离子体的相互作用以及快离子的约束也需要这些测量数据。基于绝对氘巴尔末α(D - α)辐射测量的诊断方法已开发出来并应用于C - 2装置,以测量中性密度的径向分布。同时,利用CO(2)干涉仪、汤姆逊散射和三探针诊断方法以及绝对D - α辐射测量电子密度和温度。通过阿贝尔反演得到局部D - α发射密度随时间变化的径向分布。在不同的钛沉积机器条件下获得了中性密度分布。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验