白内障术后眼的屈光度与角膜散光的一致性。

Agreement between refractive and corneal astigmatism in pseudophakic eyes.

机构信息

Department of Ophthalmology, Hospital Ramón y Cajal, Madrid, Spain.

出版信息

Cornea. 2013 Jun;32(6):783-90. doi: 10.1097/ICO.0b013e31826dd44b.

Abstract

PURPOSE

To examine the agreement and relationship between refractive and corneal astigmatism in a population of pseudophakic eyes.

METHODS

Patients of age at least 40 years, visual acuity 20/40 or better, and no ocular disease were included (n = 111). Refractive astigmatism was obtained by subjective refraction. Corneal astigmatism was measured by automated keratometry and Scheimpflug scanning analysis. All refractive values were converted to power vector components J0 and J45 for comparison and regression analysis of refractive versus corneal astigmatism. Main outcome measures were refractive and corneal astigmatism components.

RESULTS

Median single Jackson cylinder (J) was similar in refractive [0.37 diopter (D)], keratometric (0.46 D), and Pentacam astigmatism (0.49 D) (P = 0.157). Median J0 astigmatic component was slightly negative, indicating against-the-rule (ATR) astigmatism, in refractive and Scheimpflug, but not in keratometric astigmatism (refractive J0: -0.10 D; keratometric J0: 0.05 D; Pentacam J0: -0.08 D) (P = 0.049). J45 astigmatic component was nearly zero and similar with the 3 methods (P = 0.416). Refractive and keratometric J0 were significantly correlated (r = 0.7, P < 0.01), as well as the corresponding J45 values (r = 0.65, P < 0.01). Refractive and Pentacam astigmatic components were worse correlated (J0: r = 0.36, P = 0.01; J45: r = 0.45, P < 0.01). Keratometric and Pentacam astigmatic components were also significantly correlated (J0: r = 0.58, P < 0.01; J45: r = 0.51, P < 0.01).

CONCLUSIONS

Mean internal ATR astigmatism, which comes mainly from the posterior corneal surface, adds to anterior corneal astigmatism, resulting in ATR refractive astigmatism. Correlation between refractive and corneal astigmatism components is better when keratometric data are used.

摘要

目的

研究白内障术后人群的眼内离焦与角膜散光之间的一致性和关系。

方法

纳入年龄至少 40 岁、视力 20/40 或更好且无眼部疾病的患者(n=111)。通过主观验光获得离焦散光。通过自动角膜曲率计和 Scheimpflug 扫描分析测量角膜散光。将所有屈光值转换为力矢量分量 J0 和 J45 ,以比较和回归分析屈光与角膜散光的关系。主要观察指标为屈光和角膜散光分量。

结果

在屈光[0.37 屈光度(D)]、角膜曲率计(0.46 D)和 Pentacam 散光(0.49 D)中,中位数单 Jackson 圆柱(J)相似(P=0.157)。在屈光和 Scheimpflug 中,中位数 J0 散光分量略为负值,表明为逆规散光(ATR),但在角膜曲率计散光中则不是(屈光 J0:-0.10 D;角膜曲率计 J0:0.05 D;Pentacam J0:-0.08 D)(P=0.049)。J45 散光分量接近零,与 3 种方法相似(P=0.416)。屈光和角膜曲率计 J0 显著相关(r=0.7,P<0.01),相应的 J45 值也显著相关(r=0.65,P<0.01)。屈光和 Pentacam 散光分量的相关性稍差(J0:r=0.36,P=0.01;J45:r=0.45,P<0.01)。角膜曲率计和 Pentacam 散光分量也显著相关(J0:r=0.58,P<0.01;J45:r=0.51,P<0.01)。

结论

主要来自后角膜表面的平均内部 ATR 散光与前角膜散光相加,导致 ATR 屈光散光。当使用角膜曲率计数据时,屈光与角膜散光分量之间的相关性更好。