Kayashima Kenji, Habe Kazutoshi, Imai Keiko
Department of Anesthesia, Kyushukoseinenkin Hospital, Kitakyushu 806-8501.
Masui. 2012 Oct;61(10):1105-7.
The right internal jugular vein (IJV) is usually selected for pediatric central venous cannulation (CVC); however, the left is rarely selected. We investigated cases of CVC through left IJVs from Apr to Nov of 2011. In all 82 patients with the median age of 11 months, height of 72.2 cm, and weight of 7.4 kg, right IJVs were selected first for real-time ultrasound-guided CVC. Right IJVs were with median width of 7.3 mm, length of 5.0 mm, and depth of 6.8 mm. After three failed attempts through the right IJVs in three patients (3.7%), of 2 to 9 months of age out of the 82 patients, 24 G puncture needles were successfully inserted through left IJVs with the first attempt. One of the three patients, of 9 months of age with a persistent left superior vena cava, had a thinner 2.6-mm-wide right IJV and a thicker 8.3-mm-wide left IJV It was difficult but successful to insert a 0.018-inch guidewire in another patient due to a steep 90 degree angle between the left IJV and the brachiocephalic vein.
小儿中心静脉置管(CVC)通常选择右侧颈内静脉(IJV);然而,很少选择左侧。我们调查了2011年4月至11月期间通过左侧IJV进行CVC的病例。在所有82例患者中,年龄中位数为11个月,身高72.2厘米,体重7.4千克,首先选择右侧IJV进行实时超声引导下的CVC。右侧IJV的中位数宽度为7.3毫米,长度为5.0毫米,深度为6.8毫米。在82例患者中,有3例(3.7%)年龄在2至9个月的患者右侧IJV穿刺三次失败后,24G穿刺针首次尝试就成功通过左侧IJV插入。三名患者中有一名9个月大,存在永存左上腔静脉,其右侧IJV较细,宽度为2.6毫米,左侧IJV较粗,宽度为8.3毫米。由于左侧IJV与头臂静脉之间呈陡峭的90度角,在另一名患者中插入0.018英寸导丝虽然困难但最终成功。