Rippstein Pascal F, Huber Martin, Naal Florian D
Department of Foot and Ankle Surgery, Schulthess Klinik, Lengghalde 2, Zurich 8008, Switzerland.
Foot Ankle Clin. 2012 Dec;17(4):707-17. doi: 10.1016/j.fcl.2012.08.010. Epub 2012 Oct 23.
Total ankle arthroplasty (TAA) has evolved over time and modern 3-component implants offer good and reliable clinical results. Despite recent improvements, TAA is still associated with a relatively high incidence of complications. Surgeon experience seems to play the most important role. This review highlights the most common intraoperative and postoperative complications, such as malleolar fracture, impingement, cyst formation, malalignment, and loosening, and offers a differentiated concept for their management.
全踝关节置换术(TAA)随着时间的推移不断发展,现代的三组件植入物提供了良好且可靠的临床效果。尽管近期有所改进,但TAA仍与相对较高的并发症发生率相关。外科医生的经验似乎起着最重要的作用。本综述重点介绍了最常见的术中及术后并发症,如踝关节骨折、撞击、囊肿形成、排列不齐和松动,并针对其处理提出了差异化的概念。
Foot Ankle Clin. 2012-12
Zhonghua Wai Ke Za Zhi. 2011-8-1
Clin Podiatr Med Surg. 2017-10
Clin Podiatr Med Surg. 2017-10
Foot Ankle Spec. 2016-4
J Am Acad Orthop Surg. 2015-5
Foot Ankle Clin. 2012-12
Cochrane Database Syst Rev. 2015-10-17