Alignment - the process and measured orientation of the prosthetic socket relative to the foot - is important for proper function of a transtibial prosthesis. Prosthetic alignment is performed by prosthetists using visual gait observation and amputees' feedback. The aim of this study was to investigate the effect of transtibial prosthesis malalignment on the moments measured at the base of the socket: the socket reaction moments. Eleven subjects with transtibial amputation were recruited from the community. An instrumented prosthesis alignment component was used to measure socket reaction moments during ambulation under 17 alignment conditions, including nominally aligned using conventional clinical methods, and angle perturbations of 3° and 6° (flexion, extension, abduction, and adduction) and translation perturbations of 5mm and 10mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. Coronal alignment perturbations caused systematic changes in the coronal socket reaction moments. All angle and translation perturbations revealed statistically significant differences on coronal socket reaction moments compared to the nominal alignment at 30% and 75% of stance phase (P<0.05). The effect of sagittal alignment perturbations on sagittal socket reaction moments was not as responsive as that of the coronal perturbations. The sagittal angle and translation perturbations of the socket led to statistically significant changes in minimum moment, maximum moment, and moments at 45% of stance phase in the sagittal plane. Therefore, malalignment affected the socket reaction moments in amputees with transtibial prostheses.

摘要

对线 - 即假肢接受腔相对于足部的位置和测量方向 - 对于小腿假肢的正常使用非常重要。假肢对线由假肢矫形师通过观察步态和患者的反馈来完成。本研究的目的是探讨小腿假肢对线不良对接受腔底部测量到的力矩(即接受腔反作用力矩)的影响。本研究招募了 11 名小腿截肢患者作为研究对象,使用带有测量功能的假肢对线组件,在 17 种对线条件下(包括常规临床方法确定的名义对线,以及 3°和 6°的角度偏差(内收、外展、屈、伸)和 5mm 和 10mm 的平移偏差(前、后、内、外)),测量患者在步行时的接受腔反作用力矩。冠状对线偏差会导致冠状面接受腔反作用力矩发生系统变化。与名义对线相比,所有角度和平移偏差在 30%和 75%的站立阶段都会导致冠状面接受腔反作用力矩出现统计学上的显著差异(P<0.05)。矢状对线偏差对矢状面接受腔反作用力矩的影响不如冠状面偏差明显。接受腔在矢状面的角度和平移偏差会导致矢状面最小力矩、最大力矩和 45%站立阶段力矩发生统计学上的显著变化。因此,对线不良会影响小腿假肢患者的接受腔反作用力矩。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验