Suppr超能文献

中国多个中心的齐尔-尼尔森和发光二极管荧光显微镜评估。

Multicentre evaluation of Ziehl-Neelsen and light-emitting diode fluorescence microscopy in China.

机构信息

National Tuberculosis Reference Laboratory, National Center for Tuberculosis Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, People's Republic of China.

出版信息

Int J Tuberc Lung Dis. 2013 Jan;17(1):107-12. doi: 10.5588/ijtld.12.0184.

Abstract

OBJECTIVE

To assess the feasibility of using light-emitting diode fluorescence microscopy (LED-FM) in peripheral laboratories in China.

DESIGN

The performance of LED-FM and Ziehl-Neelsen (ZN) microscopy was compared on slides directly prepared from the sputum of tuberculosis (TB) suspects and follow-up patients on treatment. The examination time, fading of fluorescence-stained slides, average unit cost and qualitative user appraisal of LED-FM were also analysed.

RESULTS

Among 11 276 slides, the smear-positive rate for LED-FM was 11.2% (1263/11 276), 2.6% (294/11 276) higher than that of ZN (8.6%, 969/11 276; χ(2) 263.5, P < 0.05). The examination time for LED-FM (120.0 ± 38.9 seconds) was shorter than that for ZN (206.3 ± 75.9 s; t = 28.12, P < 0.05). For smear fading, quantitative and qualitative errors occurred within respectively 7.8 and 7.7 weeks. The average unit costs for ZN and LED-FM were respectively US$2.20 ± 0.58 and US$1.97 ± 0.71 (t = 5.08, P < 0.05). LED-FM was accepted by most laboratory technicians.

CONCLUSION

LED-FM compared favourably with ZN, with a higher smear-positive detection rate, a shorter examination time and lower unit examination cost. LED-FM may be an alternative to ZN as a cost-effective method for detecting bacilli in peripheral laboratories in China.

摘要

目的

评估在中国的基层实验室使用发光二极管荧光显微镜(LED-FM)的可行性。

设计

对直接取自肺结核(TB)疑似患者和治疗随访患者痰液标本的载玻片,比较 LED-FM 和齐-尼(ZN)显微镜的性能。还分析了 LED-FM 的检查时间、荧光染色载玻片褪色、平均单位成本和定性用户评估。

结果

在 11276 张载玻片标本中,LED-FM 的阳性检出率为 11.2%(1263/11276),比 ZN 高 2.6%(8.6%,969/11276;χ(2)263.5,P<0.05)。LED-FM 的检查时间(120.0±38.9 秒)短于 ZN(206.3±75.9 s;t=28.12,P<0.05)。对于涂片褪色,定量和定性误差分别在 7.8 和 7.7 周内发生。ZN 和 LED-FM 的平均单位成本分别为 2.20±0.58 美元和 1.97±0.71 美元(t=5.08,P<0.05)。大多数实验室技术人员都接受了 LED-FM。

结论

LED-FM 与 ZN 相比具有优势,阳性检出率更高,检查时间更短,单位检查成本更低。LED-FM 可能是 ZN 的替代方法,是中国基层实验室检测杆菌的一种具有成本效益的方法。