Keating E M, Ritter M A, Faris P M
Center for Hip and Knee Surgery, Mooresville, Indiana 46158.
J Bone Joint Surg Am. 1990 Apr;72(4):509-11.
The anatomical structures adjacent to fourteen acetabula were studied to identify structures that are at risk from acetabular screws. There were six embalmed acetabula, four acetabula from two fresh autopsy specimens, and four acetabula that were studied during two gynecological operations. Models were constructed to show where these screws can penetrate. Medially placed screws either penetrated or came dangerously close to the external iliac vein; the obturator artery, nerve, and vein; and tributaries of the internal iliac vein. To avoid injury to the medial vascular structures, screws should not be placed in the anterosuperior quadrant of the acetabulum.
对14个髋臼周围的解剖结构进行了研究,以确定有髋臼螺钉置入风险的结构。其中有6个经过防腐处理的髋臼、来自2个新鲜尸检标本的4个髋臼,以及在2次妇科手术中研究的4个髋臼。构建模型以显示这些螺钉可能穿透的位置。内侧置入的螺钉要么穿透了,要么非常接近髂外静脉、闭孔动脉、神经和静脉以及髂内静脉的分支。为避免损伤内侧血管结构,不应在髋臼的前上象限置入螺钉。