BACKGROUND

Previously, the authors demonstrated the feasibility of a pure transvesical natural orifice translumenal endoscopic surgery (NOTES) for uterine horn resection (UHR) using a rigid ureteroscope in swine as an appendectomy model. However, visualization was poor, and there was room for improvement. The authors have assessed the feasibility and safety of a revised technique that uses a 5-mm rigid laparoscope.

METHODS

Eight operations on four female pigs (35-40 kg) were performed as a proof of concept study. Four right-side operations were performed in a survival model. The surgical procedure was similar to the original technique. However, the rigid ureteroscope was replaced by a 5-mm laparoscope after modification of the access system. In addition, the clipped metal threads used for bladder closure were easily placed with a long 13-gauge needle. In the survival model, a Foley catheter was placed for 1 day.

RESULTS

The new technique provided considerably better visualization and operability than the original technique. The mean total operative time was 96.6 ± 18.2 min, and the mean estimated blood loss was 15.0 ± 13.5 ml. On postoperative day 3, pig 2 in the survival study died of peritonitis resulting from a small bowel injury. The lab results for the other pigs demonstrated no adverse events and tolerable immune responses. Necropsy showed complete healing of the vesicotomy.

CONCLUSIONS

The revised transvesical NOTES UHR technique improved the outcomes and feasibility of the original technique. This approach may be translatable to human appendectomy procedures in the future.

摘要

背景

先前,作者们证明了使用刚性输尿管镜作为阑尾切除术模型,通过经膀胱自然腔道内镜手术(NOTES)进行子宫角切除术(UHR)的可行性。然而,由于可视性较差,仍有改进的空间。作者们评估了使用 5mm 刚性腹腔镜的改良技术的可行性和安全性。

方法

作为概念验证研究,对四只雌性猪(35-40kg)进行了八次手术。四个右侧手术在存活模型中进行。手术过程与原始技术相似。然而,在修改进入系统后,刚性输尿管镜被 5mm 腹腔镜所取代。此外,用于膀胱闭合的夹式金属线很容易用长 13 号针头放置。在存活模型中,放置 Foley 导管 1 天。

结果

新技术提供了比原始技术明显更好的可视化和可操作性。平均总手术时间为 96.6±18.2 分钟,平均估计出血量为 15.0±13.5ml。在存活研究的第 3 天,猪 2 死于小肠损伤引起的腹膜炎。其他猪的实验室结果显示无不良事件和可耐受的免疫反应。尸检显示膀胱切开术完全愈合。

结论

改良的经膀胱 NOTES UHR 技术改善了原始技术的结果和可行性。这种方法将来可能适用于人类阑尾切除术。