Saleh Muneer Aziz, Ramli Ahmad Termizi, Alajeramie Yasser, Suhairul Hashim, Aliyu Abubakar Sadiq, Basri Nor Afifah
Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Skudai, Johor Bahru, Johor, Malaysia.
Radiat Prot Dosimetry. 2013 Sep;156(2):246-52. doi: 10.1093/rpd/nct061. Epub 2013 Mar 28.
An extensive survey was carried out for gamma dose rates (GDRs) in the Mersing district, Johor, Malaysia. The average value of GDR measured in the district was found to be 140 nGy h(-1), in the range of 40-355 nGy h(-1). The mean weighted dose rate to the population, annual effective dose equivalent, collective effective dose equivalent, lifetime cancer risk were 0.836 mSv y(-1), 0.171 mSv, 1.18 × 10(1) man Sv y(-1) and 6.98 × 10(-4) Sv y, respectively. An isodose map was produced for the district. One way analysis of variance was used to test for differences due to different geological formations present in the Mersing District.