Suppr超能文献

Amplatzer房间隔封堵器对小儿患者左心室功能的影响。

Impact of the Amplatzer atrial septal occluder device on left ventricular function in pediatric patients.

作者信息

Castaldi Biagio, Santoro Giuseppe, Di Salvo Giovanni, Gaio Gianpiero, Palladino Maria Teresa, D'Aiello Fabio, Iacono Carola, Pacileo Giuseppe, Calabrò Raffaele, Russo Maria Giovanna

机构信息

Pediatric Cardiology, "Ospedali dei Colli" Hospital, 2nd University of Naples, Via C. Colombo, 19, 80033, Cicciano, NA, Italy,

出版信息

Pediatr Cardiol. 2013 Oct;34(7):1645-51. doi: 10.1007/s00246-013-0695-3. Epub 2013 Apr 17.

Abstract

Percutaneous closure currently is widely considered to be the first-choice therapeutic option in the treatment of ostium secundum atrial septal defect (ASD). The Amplatzer Septal Occluder (ASO) device is the most used prosthesis, although its influence on cardiac function still is under active investigation. This study aimed to evaluate the impact of the ASO device size on left ventricular (LV) function in pediatric patients using the speckle-tracking strain imaging technology. The study enrolled 43 nonobese pediatric patients submitted to percutaneous ASD closure with the Amplatzer Septal Occluder device and grouped them according to the size of the occluding prosthesis into three groups: a small-device group (≤ 10 mm, group 1), a medium-size-device group (11-16 mm, group 2), and a large-device group (≥ 17 mm, group 3). Echocardiographic data were compared among the groups and with the data of an age-, weight-, and gender-matched control group (50 patients). The large-device group showed a significant impairment in the strain rate value of the basal LV segments. In particular, the mean basal circumferential and radial strain rate values were lower than either normal or the values of the small- and medium-device groups. However, only the absolute device diameter reached statistical significance in the multivariate analysis. The large Amplatzer Septal Occluding device significantly impaired LV systolic function, particularly that of juxtaprosthetic segments, as shown in the strain rate analysis.

摘要

经皮封堵术目前被广泛认为是继发孔型房间隔缺损(ASD)治疗的首选治疗方案。虽然其对心脏功能的影响仍在积极研究中,但Amplatzer房间隔封堵器(ASO)是最常用的假体。本研究旨在使用斑点追踪应变成像技术评估ASO装置大小对小儿患者左心室(LV)功能的影响。该研究纳入了43例接受Amplatzer房间隔封堵器经皮ASD封堵术的非肥胖小儿患者,并根据封堵假体的大小将他们分为三组:小装置组(≤10mm,第1组)、中装置组(11 - 16mm,第2组)和大装置组(≥17mm,第3组)。对各组之间以及与年龄、体重和性别匹配的对照组(50例患者)的数据进行了超声心动图数据比较。大装置组左心室基底段的应变率值有显著损害。特别是,平均基底圆周和径向应变率值低于正常组或小装置组和中装置组的值。然而,在多变量分析中只有绝对装置直径达到统计学意义。如应变率分析所示,大型Amplatzer房间隔封堵装置显著损害左心室收缩功能,尤其是假体旁节段的功能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验