Suppr超能文献

在接受肝切除术的各类疾病患者中,使用计算机断层扫描和锝-99m半乳糖基血清白蛋白闪烁扫描的集成SPECT/CT成像技术,对每个肝段的形态学肝体积与功能性肝体积之间的相关性进行研究。

Correlation between morphological and functional liver volume in each sector using integrated SPECT/CT imaging by computed tomography and technetium-99m galactosyl serum albumin scintigraphy in patients with various diseases who had undergone hepatectomy.

作者信息

Nanashima Atsushi, Abo Takafumi, Tobinaga Syuuichi, Murakami Goushi, Kido Yasuo, Fukuda Tooru, Tsuchiya Tomoshi, Matsumoto Hirofumi, Nagayasu Takeshi, Kudo Takashi

机构信息

Department of Surgery, Division of Surgical Oncology, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, Japan.

出版信息

Nucl Med Commun. 2013 Jul;34(7):652-9. doi: 10.1097/MNM.0b013e328361cd42.

Abstract

OBJECTIVES

The aim of the study was to accurately examine the functional volume (RI-vol) of the hepatic segments on single photon emission computed tomography/computed tomography (CT) fusion imaging by technetium-99m galactosyl human serum albumin scintigraphy and compare it with the RI-vol and morphological volume obtained on computed tomography (CT-vol).

METHODS

In 60 patients with various liver background statuses who had undergone hepatectomy, the RI-vol and CT-vol were examined in each sector using imaging analysis. The values from a control group (n=91) were used as reference data.

RESULTS

The mean RI-vol and CT-vol of the right liver were 64 ± 10 and 63 ± 6%, respectively, whereas the values for the left liver were 36 ± 10 and 37 ± 6%, respectively. Compared with the control group, the ratios in each hemiliver were similar. The mean RI-vol and CT-vol for each sector were also similar, and significant positive correlations were identified between the two volumes (P<0.01). In four patients with hepatic tumors involving the main hepatic vessels or the bile duct and in 10 patients who had undergone portal vein embolization, the actual RI-vol in the injured sector was significantly decreased compared with CT-vol (P<0.05). There were marked changes in functional volume in segment 6+7 and segment 2+3 after portal vein embolization (P<0.05).

CONCLUSION

Volumetric measurement using single photon emission computed tomography/CT imaging with technetium-99m galactosyl human serum albumin scintigraphy is useful for evaluating the functional volume in separated livers and offers a good reflection of the background liver status.

摘要

目的

本研究旨在通过锝-99m半乳糖基人血清白蛋白闪烁扫描单光子发射计算机断层扫描/计算机断层扫描(CT)融合成像准确检测肝段的功能体积(RI-vol),并将其与计算机断层扫描获得的RI-vol和形态学体积(CT-vol)进行比较。

方法

对60例接受肝切除术的不同肝脏背景状态的患者,使用影像分析检查每个肝段的RI-vol和CT-vol。将来自对照组(n = 91)的值用作参考数据。

结果

右肝的平均RI-vol和CT-vol分别为64±10和63±6%,而左肝的值分别为36±10和37±6%。与对照组相比,每个半肝的比例相似。每个肝段的平均RI-vol和CT-vol也相似,并且在两个体积之间发现显著的正相关(P<0.01)。在4例肝肿瘤累及主要肝血管或胆管的患者和10例接受门静脉栓塞的患者中,损伤肝段的实际RI-vol与CT-vol相比显著降低(P<0.05)。门静脉栓塞后6+7段和2+3段的功能体积有明显变化(P<0.05)。

结论

使用锝-99m半乳糖基人血清白蛋白闪烁扫描的单光子发射计算机断层扫描/CT成像进行体积测量,有助于评估分离肝脏的功能体积,并能很好地反映背景肝脏状态。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验