Faculty of Electrical Engineering and Computer Science, University of Maribor, Smetanova 17, Maribor 2000, Slovenia.
Sensors (Basel). 2013 May 14;13(5):6365-79. doi: 10.3390/s130506365.
This paper presents an improved monitoring system for the failure detection of engraving tool steel inserts during the injection molding cycle. This system uses acoustic emission PZT sensors mounted through acoustic waveguides on the engraving insert. We were thus able to clearly distinguish the defect through measured AE signals. Two engraving tool steel inserts were tested during the production of standard test specimens, each under the same processing conditions. By closely comparing the captured AE signals on both engraving inserts during the filling and packing stages, we were able to detect the presence of macro-cracks on one engraving insert. Gabor wavelet analysis was used for closer examination of the captured AE signals' peak amplitudes during the filling and packing stages. The obtained results revealed that such a system could be used successfully as an improved tool for monitoring the integrity of an injection molding process.
本文提出了一种改进的监测系统,用于在注塑周期中检测雕刻工具钢嵌件的失效。该系统使用安装在雕刻嵌件上的声发射 PZT 传感器通过声波导进行检测。因此,我们能够通过测量的声发射信号清楚地分辨缺陷。在生产标准试件的过程中,对两个雕刻工具钢嵌件进行了测试,每个嵌件的加工条件相同。通过在填充和保压阶段密切比较两个雕刻嵌件上捕获的声发射信号,我们能够检测到一个雕刻嵌件上存在宏观裂纹。使用 Gabor 小波分析对填充和保压阶段捕获的声发射信号的峰值幅度进行了更详细的研究。得到的结果表明,这样的系统可以成功地用作监测注塑过程完整性的改进工具。