Suppr超能文献

三维高分辨率磁共振成像在面肌痉挛中检测责任血管的价值:与术中高清内镜可视化的比较。

Value of 3-dimensional high-resolution magnetic resonance imaging in detecting the offending vessel in hemifacial spasm: comparison with intraoperative high definition endoscopic visualization.

机构信息

Department of Neurosurgery, University Medicine Greifswald, Germany.

出版信息

Neurosurgery. 2013 Jul;73(1):58-67; discussion 67. doi: 10.1227/01.neu.0000429838.38342.e2.

Abstract

BACKGROUND

High-resolution 3-dimensional (3-D) magnetic resonance imaging (MRI) is widely used to predict the neurovascular anatomy within the cerebellopontine angle.

OBJECTIVE

To assess the value of 3-D steady-state free precession imaging (SSFP) and time-of-flight magnetic resonance angiography (TOF MRA) in detecting the offending vessels in hemifacial spasm in comparison to intraoperative endoscopic visualization.

METHODS

42 patients underwent endoscope-assisted microvascular decompression (MVD). All available preoperative 3-D SSFP and TOF MRA images were checked. Intraoperative videos were captured by a high-definition endoscopic camera attached to endoscopes while exploring the area of facial nerve root exit zone (REZ). Evaluation of the 3-D images was performed by 2 independent groups of observers and compared with the operative findings.

RESULTS

Three-D MRI had an average positive predictive value (PPV) of 89.1% in differentiating between simple and complex compression. Mean accuracy of the images in detection of the offending vessels was 83.3% and 77% according to the first and second groups of observers, respectively. Averaged inter-observer agreement between the 2 groups of observers was substantial, with an averaged Kappa coefficient (K) of 0.56. In the simple compression group, mean accuracy was 97% and 89.4% according to the first and second groups of observers, respectively. Averaged K for agreement was substantial (K = 0.65).

CONCLUSION

According to endoscopic visualization, 3-D SSFP and TOF MRA images are accurate in detecting the offending vessels in simple compression of the facial nerve, and in predicting presence of a complex compression with variable sensitivity in identifying all offending vessels.

摘要

背景

高分辨率三维(3-D)磁共振成像(MRI)广泛用于预测桥小脑角内的神经血管解剖结构。

目的

评估三维稳态自由进动成像(SSFP)和时间飞跃磁共振血管造影(TOF MRA)在检测面肌痉挛中责任血管方面的价值,并与术中内镜可视化进行比较。

方法

42 例患者接受了内镜辅助微血管减压术(MVD)。检查了所有可用的术前 3-D SSFP 和 TOF MRA 图像。高清内镜摄像机在探查面神经神经根出口区(REZ)时捕获术中视频。由两组独立的观察者对 3-D 图像进行评估,并与手术结果进行比较。

结果

3-D MRI 在区分单纯性和复杂性压迫方面的平均阳性预测值(PPV)为 89.1%。根据第一组和第二组观察者的测量,图像在检测责任血管方面的平均准确率分别为 83.3%和 77%。两组观察者之间的平均观察者间一致性较强,平均 Kappa 系数(K)为 0.56。在单纯性压迫组中,根据第一组和第二组观察者的测量,平均准确率分别为 97%和 89.4%。观察者间一致性的平均 K 值较高(K = 0.65)。

结论

根据内镜可视化,3-D SSFP 和 TOF MRA 图像在检测面神经单纯性压迫中的责任血管方面是准确的,并能预测存在复杂压迫,对识别所有责任血管的敏感性不同。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验