特发性脊柱侧凸患者的脊柱测弯计测量。

Scoliometer measurements of patients with idiopathic scoliosis.

机构信息

Universidade de São Paulo, Ribeirão Preto, SP, Brazil.

出版信息

Braz J Phys Ther. 2013 Mar-Apr;17(2):179-84. doi: 10.1590/S1413-35552012005000081.

Abstract

BACKGROUND

Patients with idiopathic scoliosis are exposed to approximately 25 radiographic examinations of their spine throughout the clinical follow-up using the Cobb angle. Several non-invasive and radiation-free methods have been proposed to measure scoliotic deformities, including the scoliometer.

OBJECTIVES

To measure the intra- and interrater reliability of the scoliometer measurements, to assess the correlation of the values obtained by the scoliometer measurements with the Cobb angles obtained by radiography, and to assess the sensitivity and specificity of the scoliometer measurements for the different diagnostic criteria for the referral of idiopathic scoliosis.

METHOD

Sixty-four patients were selected for the study: half with idiopathic scoliosis and half without. The 17 levels of the spine of each volunteer were measured with a scoliometer in the forward bending position. The measurements were performed three times on 42 volunteers by two different raters to obtain data for calculating the reliability values. Anteroposterior radiographs were taken to determine the Cobb angles, which were then compared with the highest trunk rotation value. Sensitivity and specificity were evaluated using radiograph criteria for referral: a Cobb angle of 10º and axial trunk rotation values between 5º and 10º.

RESULTS

Excellent intrarater reliability values and very good interrater reliability values were obtained. The correlation between the scoliometer measurements and radiograph analyses was considered good (r=0.7, p<0.05). The highest sensitivity value was for a trunk rotation of 5º at 87%.

CONCLUSIONS

The scoliometer measurements showed a good correlation with the radiographic measurements.

摘要

背景

特发性脊柱侧凸患者在临床随访中,大约需要对脊柱进行 25 次 Cobb 角放射检查。已经提出了几种非侵入性和无辐射的方法来测量脊柱侧凸畸形,包括脊柱侧凸计。

目的

测量脊柱侧凸计测量的组内和组间可靠性,评估脊柱侧凸计测量值与放射学测量的 Cobb 角之间的相关性,并评估脊柱侧凸计测量值对特发性脊柱侧凸转诊的不同诊断标准的敏感性和特异性。

方法

选择 64 名患者进行研究:一半为特发性脊柱侧凸患者,一半为无特发性脊柱侧凸患者。每个志愿者的脊柱 17 个节段在向前弯曲位置用脊柱侧凸计进行测量。42 名志愿者由 2 名不同的评估者进行了 3 次测量,以获得计算可靠性值的数据。拍摄前后位 X 光片以确定 Cobb 角,然后将其与最大躯干旋转值进行比较。使用转诊的 X 光片标准评估敏感性和特异性:Cobb 角为 10°,轴向躯干旋转值为 5°至 10°。

结果

获得了极好的组内可靠性值和非常好的组间可靠性值。脊柱侧凸计测量值与放射学分析之间的相关性被认为很好(r=0.7,p<0.05)。最大的敏感性值为躯干旋转 5°时为 87%。

结论

脊柱侧凸计测量值与放射学测量值具有良好的相关性。