Suppr超能文献

心脏补片主动脉瓣叶移植的大小选择指南。

Guidelines for sizing pericardium for aortic valve leaflet grafts.

机构信息

Department of Cardiac Surgery, Boston Children's Hospital, Boston, Massachusetts 02115, USA.

出版信息

Ann Thorac Surg. 2013 Jul;96(1):e25-7. doi: 10.1016/j.athoracsur.2013.04.085.

Abstract

Surgical repair of the aortic valve with the use of leaflet grafts made from pericardium has been shown to be a viable option, particularly in children, in whom valve replacement has strong disadvantages. We present guidelines for sizing treated autologous pericardium to fabricate a leaflet graft for single-leaflet replacement. Both our clinical experience and experimental evidence indicate that effective repairs are best achieved by use of a semicircular graft with a diameter 10% to 15% greater than the sinotubular junction diameter in diastole. We also provide a simple formula to allow adjustment of these guidelines to account for variations in valve geometry and tissue properties.

摘要

使用心包制成的瓣叶移植物进行主动脉瓣的外科修复已被证明是一种可行的选择,特别是在儿童中,因为瓣膜置换具有很大的弊端。我们提出了用于测量处理过的自体心包以制造用于单瓣置换的瓣叶移植物的指南。我们的临床经验和实验证据都表明,使用直径比舒张期窦管交界处直径大 10%至 15%的半圆形移植物可以最好地实现有效的修复。我们还提供了一个简单的公式,可以根据瓣膜几何形状和组织特性的变化来调整这些指南。

相似文献

1
Guidelines for sizing pericardium for aortic valve leaflet grafts.
Ann Thorac Surg. 2013 Jul;96(1):e25-7. doi: 10.1016/j.athoracsur.2013.04.085.
3
Computational model of aortic valve surgical repair using grafted pericardium.
J Biomech. 2012 Apr 30;45(7):1199-204. doi: 10.1016/j.jbiomech.2012.01.031. Epub 2012 Feb 16.
5
Pericardial patch repair of aortic cusp perforation caused by cardiac catheterization.
J Card Surg. 1988 Jun;3(2):155-7. doi: 10.1111/j.1540-8191.1988.tb00233.x.
6
Cusp extension technique for bicuspid aortic valve in Turner-like stigmata.
Asian Cardiovasc Thorac Ann. 2004 Sep;12(3):266-9. doi: 10.1177/021849230401200320.
7
Techniques of autologous pericardial leaflet replacement for aortic valve reconstruction.
Ann Thorac Surg. 2014 Aug;98(2):743-5. doi: 10.1016/j.athoracsur.2013.11.086.
9
Reconstruction of the aortic valve leaflet with autologous pulmonary artery wall.
Eur J Cardiothorac Surg. 2021 Jan 4;59(1):269-270. doi: 10.1093/ejcts/ezaa246.
10
Truly stentless autologous pericardial aortic valve replacement: an alternative to standard aortic valve replacement.
J Thorac Cardiovasc Surg. 2011 Jan;141(1):276-83. doi: 10.1016/j.jtcvs.2010.09.038. Epub 2010 Oct 20.

引用本文的文献

1
A midterm follow-up study of the application of a confluent aortic valve neocuspidization technique with pericardium in children.
Transl Pediatr. 2023 Nov 28;12(11):1981-1991. doi: 10.21037/tp-23-289. Epub 2023 Nov 24.
2
Tissue formation and host remodeling of an elastomeric biodegradable scaffold in an ovine pulmonary leaflet replacement model.
J Biomed Mater Res A. 2024 Feb;112(2):276-287. doi: 10.1002/jbm.a.37622. Epub 2023 Sep 29.
3
A low-cost bioprosthetic semilunar valve for research, disease modelling and surgical training applications.
Interact Cardiovasc Thorac Surg. 2017 Nov 1;25(5):785-792. doi: 10.1093/icvts/ivx189.
4
Aortic valve repair update.
Gen Thorac Cardiovasc Surg. 2015 Jun;63(6):309-19. doi: 10.1007/s11748-015-0523-1. Epub 2015 Feb 5.

本文引用的文献

1
Computational model of aortic valve surgical repair using grafted pericardium.
J Biomech. 2012 Apr 30;45(7):1199-204. doi: 10.1016/j.jbiomech.2012.01.031. Epub 2012 Feb 16.
2
Single cusp replacement for aortic regurgitation.
Ann Thorac Surg. 2008 Mar;85(3):946-8. doi: 10.1016/j.athoracsur.2007.10.037.
5
Reconstruction of the aortic valve with autologous pericardium: an experimental study.
J Thorac Cardiovasc Surg. 1999 Jan;117(1):197-8. doi: 10.1016/s0022-5223(99)70493-9.
6
Aortic valve replacement with autologous pericardium: surgical technique.
J Card Surg. 1995 Jan;10(1):1-9. doi: 10.1111/j.1540-8191.1995.tb00582.x.
7
Dimensions and geometric relationships of the human aortic valve as a function of pressure.
Circ Res. 1974 Dec;35(6):871-82. doi: 10.1161/01.res.35.6.871.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验