Abstract

We used 3-dimensional computed tomographic images to create a disease-based transesophageal echocardiographic simulation system for complex congenital heart defects. We enrolled 7 pediatric patients with complex congenital heart defects in this proof-of-concept study. Preoperative computed tomographic images and intraoperative transesophageal echocardiographic images were acquired for all patients. Two- and 3-dimensional computed tomographic cross-sectional images were created to simulate the process of transesophageal echocardiographic image acquisition. Computed tomographic images simulating the midesophageal 4- and 5-chamber views, aortic valve short-axis views, long-axis views, and ascending aortic short-axis views were created to correspond with the actual transesophageal echocardiographic images from each patient. Four reviewers then evaluated the image quality of the computed tomographic images, the agreement between the echocardiographic and tomographic images, and the ability of the 3-dimensional computed tomographic full-volume and cross-sectional images to yield the spatial and temporal congruence of transesophageal echocardiograms. In most of the patients, computed tomography yielded images of good-to-excellent quality. Strong agreement was noted between the computed tomographic and transesophageal echocardiographic images acquired in the same patients. The ability of 3-dimensional computed tomography to yield the spatial and temporal congruence of transesophageal echocardiography in selected planes was also good to excellent. We found that 3-dimensional computed tomographic images can simulate the process of transesophageal echocardiography in acquiring the echocardiographic image clearly. This imaging method has the potential to be applied successfully to a disease-based transesophageal echocardiographic simulation system.

摘要

我们使用三维计算机断层扫描图像创建了一个基于疾病的经食管超声心动图模拟系统,用于复杂先天性心脏病。在这项概念验证研究中,我们纳入了7名患有复杂先天性心脏病的儿科患者。为所有患者采集了术前计算机断层扫描图像和术中经食管超声心动图图像。创建二维和三维计算机断层扫描横截面图像以模拟经食管超声心动图图像采集过程。创建模拟食管中段四腔心和五腔心视图、主动脉瓣短轴视图、长轴视图以及升主动脉短轴视图的计算机断层扫描图像,以与每位患者的实际经食管超声心动图图像相对应。然后,四名评估人员评估了计算机断层扫描图像的质量、超声心动图图像与断层扫描图像之间的一致性,以及三维计算机断层扫描全容积和横截面图像产生经食管超声心动图空间和时间一致性的能力。在大多数患者中,计算机断层扫描产生的图像质量良好至优秀。在同一患者中采集的计算机断层扫描图像与经食管超声心动图图像之间存在高度一致性。三维计算机断层扫描在选定平面产生经食管超声心动图空间和时间一致性的能力也良好至优秀。我们发现,三维计算机断层扫描图像可以清晰地模拟经食管超声心动图获取超声心动图图像的过程。这种成像方法有可能成功应用于基于疾病的经食管超声心动图模拟系统。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验