Suppr超能文献

Distal movement of upper permanent molars using midpalatal mini-implant.

作者信息

de Lira Ana de Lourdes Sá, Prado Sávio, Araújo Mônica Tirre, Sant'Anna Eduardo Franzotti, Ruellas Antonio Carlos de Oliveira

机构信息

UFPI, Brazil.

出版信息

Dental Press J Orthod. 2013 Mar 15;18(2):18.e1-5. doi: 10.1590/s2176-94512013000200006.

Abstract

OBJECTIVE

To assess whether palatal mini-implants are effective as direct anchorage for distal movement of the upper molars.

METHODS

It was used an acrylic model of the upper dental arch. After making a groove in the region corresponding to dental alveolus, acrylic teeth were fixed in this groove with #7 wax, with the roots being previously immersed in adhesive wax. The orthodontic appliance was placed according to the Edgewise technique and then a mini-implant (SIN, São Paulo, Brazil) was inserted at the site corresponding to the palatal raphe. A 0.019 x 0.025-in stainless steel archwire was made and attached to the upper arch with elastics. A transpalatal bar (0.019 x 0.025-in) was mounted and two hooks were welded to it in order to retain chain elastics (Unitek, Brazil) to be connected to the mini-implant under a force of 1.5 N on each side. The maxillary model was immersed in water 40 times and photographed after each immersion, for observing dental movements. Analysis of variance (ANOVA) and Tukey's test were used for analyzing the obtained data.

RESULTS

Molars displaced distally 3.1 mm, in average, with distal inclination ranging from 3 to 5 mm.

CONCLUSIONS

Molar movements occurred due to distal inclination, with a slight rotation and no extrusive effect.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验