Reproducibility of cumulative work, heart rate and blood pressure response during stepwise versus continuous load increment during a maximal bicycle ergometer test.

作者信息

Michelsen S

机构信息

Division of Cardiology, Vestfold Central Hospital, Tønsberg, Norway.

出版信息

Scand J Clin Lab Invest. 1990 Jun;50(4):409-15. doi: 10.3109/00365519009091599.

Abstract

The reproducibility of physical capacity expressed as cumulative work (CW) and work pulse (WP) as well as haemodynamic response to maximal exercise was evaluated by two different principles for increasing work load during a maximal bicycle ergometer exercise test: (i) stepwise increment (SI) of 50 Watts (W) every fourth minute; (ii) continuous increment (CI) of 10 W at the end of every minute, both with a starting load of 50 W. Forty apparently healthy men aged 29-69 (mean 47) years performed two tests with a mean interval of 17 (3-43) days. Group A: 10 men who did SI twice; group B: 10 who repeated CI; group C: 10 men who performed SI and CI alternatively; group D: 10 men who did SI in the morning vs afternoon. Error % (percentage of the absolute difference of the mean of two values) was 3.9 for CW in group A vs 7.8 in group B (p less than 0.05). The error % of heart rates at submaximal work levels were lower with SI than CI. Mean CW in group C was 182.3 +/- 65.1 kJ for CI and 154.8 +/- 48.8 kJ for SI (p less than 0.01), whereas the mean exercise time was 1206 +/- 297 s and 1089 +/- 197 s respectively (p less than 0.01). Group D subjects achieved 142.7 +/- 49.4 kJ in the morning and 134.4 +/- 48.8 kJ in the afternoon (p less than 0.05). No significant differences were noted for WP in groups A-D. A better reproducibility for CW was found for SI, whereas both tests had similar reproducibility for heart rate and blood pressure response during maximal exercise.

摘要

在最大运动强度的自行车测力计运动测试中,通过两种不同的增加负荷原则,对以累积功(CW)和功脉冲(WP)表示的身体能力的可重复性以及最大运动时的血流动力学反应进行了评估:(i)每四分钟逐步增加50瓦(W)(逐步递增,SI);(ii)每分钟末持续增加10 W(持续递增,CI),两者起始负荷均为50 W。40名年龄在29至69岁(平均47岁)的明显健康男性进行了两次测试,平均间隔时间为17(3至43)天。A组:10名男性进行了两次SI测试;B组:10名重复进行CI测试;C组:10名男性交替进行SI和CI测试;D组:10名男性在上午与下午进行SI测试。A组CW的误差百分比(两个值均值的绝对差的百分比)为3.9%,而B组为7.8%(p<0.05)。次最大工作水平时心率的误差百分比,SI低于CI。C组CI的平均CW为182.3±65.1千焦,SI为154.8±48.8千焦(p<0.01),而平均运动时间分别为1206±297秒和1089±197秒(p<0.01)。D组受试者上午达到142.7±49.4千焦,下午达到134.4±48.8千焦(p<0.05)。A - D组WP无显著差异。SI的CW再现性更好,而在最大运动期间,两种测试在心率和血压反应方面具有相似的再现性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验