用气相色谱-电子俘获检测器测定指示性多氯联苯(PCBs)。

Determination of indicator polychlorinated biphenyls (PCBs) by gas chromatography-electron capture detector.

机构信息

Nuclear Chemistry Environmental Research Center, Ghana Atomic Energy Commission, Box LG. 80, Legon, Accra, Ghana.

出版信息

Chemosphere. 2013 Nov;93(8):1556-60. doi: 10.1016/j.chemosphere.2013.08.001. Epub 2013 Sep 6.

Abstract

An effective method for determination of indicator polychlorinated biphenyls (PCBs) has been validated using gas chromatography (GC) equipped with electron capture detector (ECD). The GC-ECD method was validated by determining the linear range (working range) for determination of the compounds, minimum detectable quantities (MDQ), the precision and accuracy of the method for the analysis of the compounds. MDQ obtained for the compounds ranges from 0.0005 to 0.002 ng. Indeed the method was found to be more sensitive as the number of chlorine atoms attached to the biphenyl increases. The precision and accuracy of the GC method validated ranges from 2.4% to 14.5% and -7.0% to 14.6% respectively. Coefficient of variation associated with the repeatability of the retention times and corresponding peak areas was found to be 0.0001-0.0007 for the retention times and 0.0014-0.059 for the peak areas. Percentage recoveries for the compounds were in the range of 95.7-101.0%. The validated method was then applied to determine levels of indicator PCBs in sediments sampled from eleven sampling points along the Lake Bosuntwi in Ghana and the highest PCB load of 19.17 ng g(-1) was recorded at Pipie No. 2. PCB 52 and PCB 101 were found to be the most ubiquitous indicator PCBs in the study area, both with 90.91% occurrence.

摘要

一种使用配备电子捕获检测器(ECD)的气相色谱(GC)测定指示性多氯联苯(PCBs)的有效方法已经过验证。通过测定化合物的线性范围(工作范围)、最小可检测量(MDQ)、方法对化合物分析的精密度和准确度来验证 GC-ECD 方法。化合物的 MDQ 范围为 0.0005 至 0.002ng。事实上,随着联苯上氯原子数量的增加,该方法的灵敏度也随之提高。GC 方法的精密度和准确度验证范围分别为 2.4%至 14.5%和-7.0%至 14.6%。与保留时间和相应峰面积的重复性相关的变异系数分别为 0.0001-0.0007 保留时间和 0.0014-0.059 峰面积。化合物的回收率在 95.7-101.0%范围内。然后将验证后的方法应用于测定加纳博苏姆推湖 11 个采样点采集的沉积物中的指示性 PCB 水平,在 2 号皮皮(Pipie)点记录到的最高 PCB 负荷为 19.17ng/g。在研究区域中,PCB52 和 PCB101 是最普遍存在的指示性 PCB,均为 90.91%出现。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验