Khan Yasmin, Konan Sujith, Sorene Elliot
Department of Trauma & Orthopaedics, University College Hospital , London , UK.
J Plast Surg Hand Surg. 2014 Apr;48(2):136-8. doi: 10.3109/2000656X.2013.834612. Epub 2013 Sep 12.
This study reports a case of revision of a failed Swanson silastic interpositional wrist replacement to a Universal 2 (KMI Medical Inc., San Diego, CA, Jan 2009) total wrist arthroplasty, in a 68-year-old woman with rheumatoid arthritis and pyrophosphate arthropathy. At the 2-year follow-up, the patient was pain-free and was able to perform all activities of daily living, documented by subjective assessment and objective scores. The disabilities of the arm, shoulder, and hand (DASH) scores improved from 98.3 preoperatively to 55.1 postoperatively. A failed Swanson silastic interpositional wrist replacement may be successfully revised to an uncemented primary wrist replacement with good functional results at early follow-up.
本研究报告了一例将失败的斯旺森硅橡胶腕关节置换翻修为通用2型(KMI医疗公司,加利福尼亚州圣地亚哥,2009年1月)全腕关节置换的病例,患者为一名68岁患有类风湿性关节炎和焦磷酸关节病的女性。在2年的随访中,通过主观评估和客观评分记录显示,患者无痛,能够进行所有日常生活活动。手臂、肩部和手部功能障碍(DASH)评分从术前的98.3改善至术后的55.1。失败的斯旺森硅橡胶腕关节置换可成功翻修为非骨水泥型初次腕关节置换,早期随访时功能结果良好。