* Audiology and Speech Pathology, The University of Melbourne , Victoria , Australia.
Int J Audiol. 2013 Dec;52(12):808-15. doi: 10.3109/14992027.2013.832416. Epub 2013 Sep 20.
Differences in fundamental frequency (F0) contour peak alignment contribute to the perception of pitch accents in speech intonation. The present study assessed the discrimination of differences in F0 contour peak alignment by adolescent users of cochlear implants (CIs).
In Experiment 1, subjects discriminated between rise-fall F0 contours located early in the syllable and those aligned late. Recorded utterances with manipulated F0 were used as stimuli and all subjects wore a unilateral CI. In Experiment 2, bilaterally-implanted subjects repeated Experiment 1 in the bilateral condition.
Twenty-one CI users aged 12-21 years participated. A normally-hearing control group (n = 20) also completed Experiment 1.
Listeners with normal hearing (NH) could discriminate between F0 peaks differing by 80 ms or more. Results varied among the CI users, with only four users displaying a pattern of results similar to that of the NH listeners. Sixteen CI users responded inconsistently or at chance levels (p > 0.05; binomial test). Ten CI users who were bilaterally implanted completed the tests in unilateral and bilateral listening conditions.
Results suggest that CI users may have difficulty discriminating between F0 alignment and that use of bilateral implants did not provide an advantage to discrimination.
基频(F0)轮廓峰值对准的差异导致言语语调中重音的感知。本研究评估了人工耳蜗(CI)使用者对 F0 轮廓峰值对准差异的辨别能力。
在实验 1 中,受试者对位于音节早期的上升-下降 F0 轮廓与晚期对齐的 F0 轮廓进行了区分。使用经过操纵 F0 的记录语音作为刺激,所有受试者都佩戴单侧 CI。在实验 2 中,双侧植入者在双侧条件下重复实验 1。
21 名 12-21 岁的 CI 用户参与了研究。一个正常听力对照组(n = 20)也完成了实验 1。
听力正常的听众(NH)可以辨别 F0 峰值相差 80 毫秒或更多的情况。CI 用户的结果各不相同,只有四名用户的结果模式与 NH 听众相似。16 名 CI 用户的反应不一致或随机水平(p > 0.05;二项式检验)。完成单侧和双侧听力条件下测试的 10 名双侧植入者 CI 用户。
结果表明,CI 用户可能难以辨别 F0 对准,并且使用双侧植入物并不能提供辨别优势。