Suppr超能文献

校正用于阈值扫视矢量视动视野检查(SVOP)的液晶显示器亮度不均匀性。

Correcting LCD luminance non-uniformity for threshold Saccadic Vector Optokinetic Perimetry (SVOP).

作者信息

Perperidis Antonios, Murray Ian, Brash Harry, McTrusty Alice, Cameron Lorraine, Fleck Brian, Minns Robert

出版信息

Annu Int Conf IEEE Eng Med Biol Soc. 2013;2013:1636-9. doi: 10.1109/EMBC.2013.6609830.

Abstract

The accurate assessment of visual field function can provide valuable information on a range of visual disorders. Saccadic Vector Optokinetic Perimetry (SVOP) is a novel instrument for measuring supra-threshold visual fields in young children who are otherwise unable to perform Automated Static Perimetry (ASP). However, limitations in Liquid Crystal Display (LCD) technology restrict the ability of SVOP to determine threshold values at various points in the visual field, often required in detailed perimetry examinations. This paper introduces a purpose-specific LCD luminance non-uniformity compensation approach to address this limitation. Thorough quantitative evaluation identifies the effectiveness of the proposed approach in (i) compensating for luminance non-uniformities across an LCD, and (ii) enabling SVOP to perform accurate and precise threshold visual field tests. The findings demonstrate that SVOP provides a promising alternative to the current threshold ASP standard (Humphrey Field Analyser).

摘要

对视野功能的准确评估能够为一系列视觉障碍提供有价值的信息。扫视矢量视动视野计(SVOP)是一种用于测量那些无法进行自动静态视野计(ASP)检测的幼儿超阈值视野的新型仪器。然而,液晶显示器(LCD)技术的局限性限制了SVOP在视野中各个点确定阈值的能力,而这在详细的视野检查中通常是需要的。本文介绍了一种针对特定目的的LCD亮度不均匀性补偿方法来解决这一局限性。全面的定量评估确定了所提出方法在以下两方面的有效性:(i)补偿LCD上的亮度不均匀性,以及(ii)使SVOP能够进行准确且精确的阈值视野测试。研究结果表明,SVOP为当前的阈值ASP标准(Humphrey视野分析仪)提供了一种有前景的替代方案。

相似文献

1
Correcting LCD luminance non-uniformity for threshold Saccadic Vector Optokinetic Perimetry (SVOP).
Annu Int Conf IEEE Eng Med Biol Soc. 2013;2013:1636-9. doi: 10.1109/EMBC.2013.6609830.
2
Saccadic Vector Optokinetic Perimetry (SVOP): a novel technique for automated static perimetry in children using eye tracking.
Annu Int Conf IEEE Eng Med Biol Soc. 2013;2013:3186-9. doi: 10.1109/EMBC.2013.6610218.
3
Detection and characterisation of visual field defects using Saccadic Vector Optokinetic Perimetry in children with brain tumours.
Eye (Lond). 2018 Oct;32(10):1563-1573. doi: 10.1038/s41433-018-0135-y. Epub 2018 Jun 7.
4
Saccadic vector optokinetic perimetry in children with neurodisability or isolated visual pathway lesions: observational cohort study.
Br J Ophthalmol. 2016 Oct;100(10):1427-32. doi: 10.1136/bjophthalmol-2015-307208. Epub 2016 Jan 6.
5
Clinical applicability of the Saccadic Vector Optokinetic Perimeter in children with and without visual impairment.
Clin Exp Optom. 2019 Jan;102(1):70-78. doi: 10.1111/cxo.12803. Epub 2018 Jun 25.
9
Development of an Age-corrected Normative Database for Saccadic Vector Optokinetic Perimetry (SVOP).
J Glaucoma. 2020 Dec;29(12):1106-1114. doi: 10.1097/IJG.0000000000001651.
10
Feasibility of saccadic vector optokinetic perimetry: a method of automated static perimetry for children using eye tracking.
Ophthalmology. 2009 Oct;116(10):2017-26. doi: 10.1016/j.ophtha.2009.03.015. Epub 2009 Jun 27.

引用本文的文献

2
Speed and accuracy of saccades in patients with glaucoma evaluated using an eye tracking perimeter.
BMC Ophthalmol. 2020 Jun 30;20(1):259. doi: 10.1186/s12886-020-01528-4.
4
Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry.
Transl Vis Sci Technol. 2016 Aug 31;5(4):15. doi: 10.1167/tvst.5.4.15. eCollection 2016 Aug.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验