Suppr超能文献

倒置的Endurant髂支支架型人工血管治疗髂总动脉瘤。

The upside down Endurant iliac limb stent graft for treatment of a common iliac artery aneurysm.

作者信息

Koike Yuya, Nishimura Jun-ichi, Hase Soichiro, Yamasaki Motoshige

机构信息

1Department of Interventional Radiology, Kawasaki Saiwai Hospital, Kanagawa, Japan.

出版信息

Vasc Endovascular Surg. 2014 Jan;48(1):58-60. doi: 10.1177/1538574413510615. Epub 2013 Oct 30.

Abstract

Endovascular repair of the coverage from the common iliac artery to the external iliac artery after the internal iliac artery embolization has been proven to be a safe and effective treatment in isolated iliac artery aneurysms. But in cases in which the diameter of the proximal sealing zone is larger than that of the distal sealing zone, a reverse-tapered device is needed. We described the off-label use of the Endurant iliac limb stent graft in an upside down configuration to accommodate this diameter mismatch.

摘要

在髂内动脉栓塞后,从髂总动脉到髂外动脉进行血管腔内修复已被证明是治疗孤立性髂动脉瘤的一种安全有效的方法。但在近端密封区直径大于远端密封区直径的情况下,则需要使用逆向锥形装置。我们描述了Endurant髂支支架型人工血管以倒置配置进行的超说明书使用,以适应这种直径不匹配的情况。