Beatrice M G, Stanaszek W F, Allen L V, Stanton G K, Covington T R
Am J Hosp Pharm. 1975 Nov;32(11):1133-7.
The stability of a combination of hydroxyzine hydrochloride and atropine sulfate stored in syringes was studied. Syringes containing the two drugs were stored at 25 C and 3 C for ten days and analyzed at specific time intervals. Absorption spectra, chromatographic characteristics and pH were determined. Results showed the admixture to be stable for ten days at room temperature or under refrigeration. The technique used would probably not detect any significant degradation of atropine sulfate unless the reaction occurred with the hydroxyzine hydrochloride.
研究了储存在注射器中的盐酸羟嗪和硫酸阿托品组合的稳定性。含有这两种药物的注射器在25℃和3℃下储存10天,并在特定时间间隔进行分析。测定了吸收光谱、色谱特征和pH值。结果表明,该混合物在室温或冷藏条件下10天内稳定。除非硫酸阿托品与盐酸羟嗪发生反应,否则所用技术可能无法检测到硫酸阿托品的任何显著降解。