HIV screening assays have gone through several generations of development in an effort to narrow the "window period" of detection. Utilizing a fourth generation HIV screening assay has the potential to detect earlier HIV infection, thus reducing HIV-1 transmission.
To identify acute infections to decrease HIV transmission in San Diego County.
Serum specimens were collected from clients seen by multiple submitters in San Diego County. All acceptable specimens were screened using the 4th Gen Combo Assay. Initially reactive specimens were repeated in duplicate and if repeatedly reactive, were confirmed by HIV-1 Immunofluorescent Antibody Assay (IFA). IFA negative/inconclusive specimens were sent for HIV-1 NAT and HIV-2 antibody testing to referral laboratories. BioRad Multispot HIV-1/HIV-2 Rapid Test was also performed on a subset of specimens.
Of 14,559 specimens received in 20 months, 14,517 specimens were tested. Of the 14,517 specimens that were tested, a total of 279 (1.9%) specimens were CIA repeatedly reactive and 240 of the 279 confirmed by HIV-1 IFA. Thirty-nine gave IFA negative/inconclusive result and 30 were further tested for HIV-1 NAT and 36 for HIV-2 antibody. Thirteen specimens were considered false positives by CIA and 17 specimens were classified as acute infections. Eleven of 39 IFA negative/inconclusive specimens were further tested by Multispot. Five of the 11 were positive by Multispot.
The fourth generation Abbott ARCHITECT HIV Ag/Ab Combo Assay identified 17 patients who may have been missed by the prior HIV-1 screening assay used at San Diego County Public Health Laboratory.
为了缩小检测的“窗口期”,HIV 筛查检测经历了几代人的发展。使用第四代 HIV 筛查检测有可能更早地检测到 HIV 感染,从而降低 HIV-1 的传播。
为了减少圣地亚哥县的 HIV 传播,确定急性感染病例。
从圣地亚哥县的多个送检者处采集血清标本。所有合格的标本均使用第四代 Combo 检测法进行筛查。最初反应性的标本进行重复检测,如果仍然反应性,则通过 HIV-1 免疫荧光抗体检测(IFA)进行确认。IFA 阴性/不确定的标本被送往参考实验室进行 HIV-1 NAT 和 HIV-2 抗体检测。还对一部分标本进行了 BioRad Multispot HIV-1/HIV-2 快速检测。
在 20 个月内收到的 14559 个标本中,共检测了 14517 个标本。在接受检测的 14517 个标本中,共有 279 个(1.9%)标本 CIA 重复反应性,其中 240 个通过 HIV-1 IFA 得到确认。39 个标本的 IFA 结果为阴性/不确定,30 个标本进一步进行了 HIV-1 NAT 检测,36 个标本进行了 HIV-2 抗体检测。13 个标本被 CIA 判定为假阳性,17 个标本被归类为急性感染。11 个 IFA 阴性/不确定的标本通过 Multispot 进一步检测。其中 5 个标本通过 Multispot 检测呈阳性。
第四代 Abbott ARCHITECT HIV Ag/Ab Combo 检测法发现了 17 名可能被圣地亚哥县公共卫生实验室之前使用的 HIV-1 筛查检测法漏检的患者。