Suppr超能文献

髋关节骨关节炎患者行短柄髋关节置换术疗效评估中的生活质量

Quality of live of patients in the evaluation of outcomes of short stem hip arthroplasty for hip osteoarthritis.

作者信息

Tomaszewski Wiesław, Kotela Ireneusz, Kawik Lukasz, Bednarenko Marcin, Lorkowski Jacek, Kotela Andrzej

机构信息

College of Physiotherapy, Wrocław, Poland.

Clinical Department of Orthopedics and Traumatology - Central Clinical Hospital of the Ministry of Interior in Warsaw, Poland.

出版信息

Ortop Traumatol Rehabil. 2013 Oct 31;15(5):439-57. doi: 10.5604/15093492.1084359.

Abstract

BACKGROUND. The aim of the study was to evaluate clinical outcomes and broadly defined quality of life in patients with hip osteoarthritis after short stem hip arthroplasty. MATERIAL AND METHODS. The study enrolled patients operated on at the Trauma and Orthopedics Department of St. Luke's Regional Hospital in Tarnów in the years 2008-2010. The experimental group consisted of 67 patients aged 22 to 77 years (average age 54.0 years) who received Proxima short stem implants (DePuy, J&J, USA). The control group consisted of 68 patients, operated on at the same department and in the same period, who were implanted with the ABG II prosthesis with a classic anatomical stem (average age 62.2 years). The average duration of hospital stay was 8 days. Follow-up examinations were scheduled at 6 weeks, 3 months and subsequently once a year. Post-operative outcomes were evaluated with the Harris Hip Score (HHS), WOMAC index and NRS. RESULTS. Analysis of HHS scores in the experimental group showed that 89.6% of the patients demonstrated excellent and good outcomes. The hip range of motion improved significantly after arthroplasty compared to preoperative values. The mean standardized extended WOMAC score was 85.5. Pain intensity in the experimental group decreased significantly after surgery. The mean preoperative NRS score was 6.6 vs. 1.0 after surgery. The outcomes in the control group were also excellent and good, but far worse than those in the experimental group as regards both clinical status and quality of life. A comparison of HHS scores showed statistically significant differences between the groups (p=0.018). The mean WOMAC score in the control group was 77.0, which is a statistically significant difference compared to the figure in the experimental group (p=0.001). Both groups had lower NRS scores after surgery, but the values were significantly worse in the control group (p=0.001). CONCLUSIONS. The outcomes of Proxima short stem arthroplasty in patients with hip osteoarthritis were better than the outcomes of patients who were implanted with the classic anatomical ABG stem. Pain reduction and an increased hip range of motion had the strongest impact on improving patients' quality of life after short stem prosthesis hip arthroplasty.

摘要

背景。本研究的目的是评估短柄髋关节置换术后髋骨关节炎患者的临床疗效及广义定义的生活质量。材料与方法。本研究纳入了2008年至2010年在塔尔努夫圣卢克地区医院创伤与矫形外科接受手术的患者。实验组由67例年龄在22至77岁(平均年龄54.0岁)的患者组成,他们接受了Proxima短柄植入物(美国强生公司DePuy)。对照组由68例同期在同一科室接受手术的患者组成,他们植入了带有经典解剖柄的ABG II假体(平均年龄62.2岁)。平均住院时间为8天。随访检查安排在术后6周、3个月,随后每年进行一次。采用Harris髋关节评分(HHS)、WOMAC指数和数字评分量表(NRS)评估术后疗效。结果。实验组HHS评分分析显示,89.6%的患者疗效为优或良。与术前相比,关节置换术后髋关节活动范围显著改善。标准化扩展WOMAC平均评分为85.5。实验组术后疼痛强度显著降低。术前NRS平均评分为6.6,术后为1.0。对照组的疗效也为优或良,但在临床状况和生活质量方面均远逊于实验组。HHS评分比较显示两组间存在统计学显著差异(p = 0.018)。对照组WOMAC平均评分为77.0,与实验组相比有统计学显著差异(p = 0.001)。两组术后NRS评分均较低,但对照组的值明显更差(p = 0.001)。结论。髋骨关节炎患者接受Proxima短柄关节置换术的疗效优于植入经典解剖型ABG柄的患者。短柄假体髋关节置换术后,疼痛减轻和髋关节活动范围增加对改善患者生活质量影响最大。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验