The feasibility of beat-to-beat detection of His-Purkinje activity by finite element method.

作者信息

Ishijima M, Kimata S, Kasanuki H, Sakurai Y

机构信息

Institute of Biomedical Engineering, Tokyo Women's Medical College, Japan.

出版信息

Pacing Clin Electrophysiol. 1987 Sep;10(5):1107-16. doi: 10.1111/j.1540-8159.1987.tb06129.x.

DOI:10.1111/j.1540-8159.1987.tb06129.x
PMID:2444934
Abstract

A noninvasive method has been applied on human and canine subjects to observe beat-to-beat activity of the His-Purkinje system without using signal averaging. Recordings were performed with multiple Ag/AgCl electrodes, very low noise, high gain amplifiers and by analog filtering. The subjects were in a supine position during the recording. In order to reduce random noise inherent in the high-gain body surface recording, a finite element method (FEM) was applied to calculate His-Purkinje activity. The dimensional relationship between electrode sites, necessary for the calculation, was pre-estimated by x-ray computed tomographs of the subject. A prominent waveform was observed between the atrial and ventricular complexes and corresponded to His bundle activity which was simultaneously recorded by an intracardiac electrode (on every beat). It was, however, difficult to recognize the His-Purkinje activity during inhalation due to the thoracic electromyogram on some human subjects. This interference could theoretically be reduced by increasing the number of body surface electrodes used for this technique.

摘要

相似文献

1
The feasibility of beat-to-beat detection of His-Purkinje activity by finite element method.
Pacing Clin Electrophysiol. 1987 Sep;10(5):1107-16. doi: 10.1111/j.1540-8159.1987.tb06129.x.
2
Beat to beat surface recording and averaging of His-Purkinje activity in man.
J Electrocardiol. 1983 Oct;16(4):355-62. doi: 10.1016/s0022-0736(83)80085-5.
3
Noninvasive recording of His-Purkinje system [HPS] activity in man on beat-to-beat basis.在人体上逐搏无创记录希氏-浦肯野系统[HPS]活动。
Pacing Clin Electrophysiol. 1982 Jul;5(4):506-11. doi: 10.1111/j.1540-8159.1982.tb02269.x.
4
Surface recording of His-Purkinje activity on an every-beat basis without digital averaging.
Circulation. 1981 Apr;63(4):948-52. doi: 10.1161/01.cir.63.4.948.
5
Noninvasive recording of His-Purkinje activity in man by ORS-triggered signal averaging.
Circulation. 1978 Jul;58(1):95-102. doi: 10.1161/01.cir.58.1.95.
6
Statistically compensated averaging method for noninvasive recording of his-purkinje activity.用于无创记录希氏-浦肯野系统活动的统计补偿平均法。
Biomed Sci Instrum. 1978;14:129-32.
7
Noninvasive recording of the his-purkinje system electrical activity by a digital system design.通过数字系统设计对希氏-浦肯野系统电活动进行无创记录。
J Biomed Eng. 1981 Apr;3(2):147-52. doi: 10.1016/0141-5425(81)90009-1.
8
Diverse characteristics in potential waveform of His-Purkinje system--experimental and simulation studies.
Jpn Circ J. 1988 Feb;52(2):188-96. doi: 10.1253/jcj.52.188.
9
Application of beat-to-beat techniques.逐搏技术的应用。
Pacing Clin Electrophysiol. 1990 Dec;13(12 Pt 2):2148-55. doi: 10.1111/j.1540-8159.1990.tb06958.x.
10
Recording of surface His-Purkinje potentials.记录体表希氏束-浦肯野电位。
Med Biol Eng Comput. 1985 Jul;23(4):365-76. doi: 10.1007/BF02441591.