Alvarez-Arenal Angel, Brizuela-Velasco Aritza, DeLlanos-Lanchares Hector, Gonzalez-Gonzalez Ignacio
Professor and Head, Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, Oviedo, Spain.
Clinical Assistant Professor, Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, Oviedo, Spain.
J Prosthet Dent. 2014 Sep;112(3):508-14. doi: 10.1016/j.prosdent.2013.12.004. Epub 2014 Feb 21.
The design of a mandibular fixed complete denture can influence periimplant bone loss. However, the design that transfers the greatest stress to the periimplant bone is not well documented.
The purpose of this study was to assess the stress distribution associated with splinted and nonsplinted implant-supported mandibular fixed complete denture designs.
Three-dimensional finite element models simulating 6 osseointegrated implants were created in the mandible to support a cobalt-chromium alloy and feldspathic porcelain veneering framework. One model simulated a 1-piece framework, and the other models simulated 2-piece and 3-piece frameworks. Axial and oblique loads were applied to the frameworks.
For all the models, the greatest stress values were recorded in the periimplant bone of posterior implants, with differences between the left and right sides. The axial load transferred greater stress values to the periimplant bone than did the oblique load. The lowest periimplant bone stress values were observed in the 3-piece framework model at all implant locations, with the exception of implants placed in the canine region.
A framework separated into 3 pieces transfers the least stress to the periimplant bone.
下颌固定全口义齿的设计会影响种植体周围骨质流失。然而,关于哪种设计会给种植体周围骨组织带来最大应力的相关记录并不完善。
本研究旨在评估与夹板式和非夹板式种植体支持的下颌固定全口义齿设计相关的应力分布情况。
在下颌骨中创建模拟6个骨整合种植体的三维有限元模型,以支持钴铬合金和长石质瓷贴面框架。一个模型模拟一体式框架,其他模型模拟两件式和三件式框架。对框架施加轴向和斜向载荷。
对于所有模型,后牙种植体周围骨组织记录到的应力值最大,左右两侧存在差异。轴向载荷比斜向载荷将更大的应力值传递至种植体周围骨组织。除了位于尖牙区域的种植体,在所有种植体位置,三件式框架模型中观察到的种植体周围骨应力值最低。
分为三件的框架对种植体周围骨组织传递的应力最小。