Thresholds for microcavitation of bovine and porcine melanosomes were determined using nanosecond laser pulses in the near-infrared (1000 to 1319 nm) wavelength regime. Isolated melanosomes were irradiated by single pulses (10 or 50 ns) using a Q-switched Spectra Physics Nd:YAG laser coupled with an optical parametric oscillator (1000 to 1200 nm) or a continuum laser at 1319 nm. Time-resolved nanosecond strobe photography after the arrival of the irradiation beam allowed imaging of microcavitation events. Average fluence thresholds for microcavitation increased nonlinearly with increasing wavelength from ∼0.5 J/cm2 at 1000 nm to 2.6 J/cm2 at 1319 nm. Fluence thresholds were also measured for 10-ns pulses at 532 nm and found to be comparable to visible nanosecond pulse values published in previous reports. Calculated melanosome absorption coefficients decreased from 925 cm-1 at 1000 nm to 176 cm-1 at 1319 nm. This trend was found to be comparable to the decrease in retinal pigmented epithelial layer absorption coefficients reported over the same wavelength region. Estimated corneal total intraocular energy retinal damage threshold values were determined in order to compare to current and proposed maximum permissible exposure (MPE) safe levels. Results from this study support recently proposed changes to the MPE levels.
采用纳秒激光脉冲在近红外(1000 至 1319nm)波长范围内测定牛和猪黑色素体的微空化阈值。使用 Q 开关 Spectra Physics Nd:YAG 激光与光学参量振荡器(1000 至 1200nm)或 1319nm 连续波激光对分离的黑色素体进行单次脉冲(10 或 50ns)照射。在辐照光束到达后进行的纳秒级频闪摄影允许对微空化事件进行成像。微空化的平均辐照阈值随波长的增加呈非线性增加,从 1000nm 的约 0.5 J/cm2 增加到 1319nm 的 2.6 J/cm2。还测量了 10ns 脉冲在 532nm 时的阈值,并发现与以前报告的可见光纳秒脉冲值相当。计算出的黑色素体吸收系数从 1000nm 的 925cm-1 降低到 1319nm 的 176cm-1。这种趋势与在相同波长范围内报道的视网膜色素上皮层吸收系数的降低相当。为了与当前和建议的最大允许暴露(MPE)安全水平进行比较,确定了角膜总眼内能量视网膜损伤阈值。本研究的结果支持对 MPE 水平的最近提议的更改。