The objective of this systematic review was to evaluate the effect of mechanical instruments on the biocompatibility of titanium dental implant surfaces.
MEDLINE, Cochrane-CENTRAL and EMBASE databases were searched up to December 2013, to identify controlled studies on the ability of cells to adhere and colonize non-contaminated and contaminated, smooth and rough, titanium surfaces after instrumentation with different mechanical instruments.
A comprehensive search identified 1893 unique potential papers. Eleven studies met the inclusion criteria and were selected for this review. All studies were in vitro studies. Most studies used titanium discs, strips and cylinders. The air abrasive was the treatment mostly evaluated. The available studies had a high heterogeneity which precluded any statistical analysis of the data. Therefore, the conclusions are not based on quantitative data. Instrumentation seems to have a selective influence on the attachment of different cells. In the presence of contamination, plastic curettes, metal curettes, rotating titanium brushes and an ultrasonic scaling system with a carbon tip and polishing fluid seem to fail to restore the biocompatibility of rough titanium surfaces. The air-powder abrasive system with sodium bicarbonate powder does not seem to affect the fibroblast-titanium surface interaction after treatment of smooth or rough surfaces, even in the presence of contamination.
The available data suggest that treatment with an air-powder abrasive system with sodium bicarbonate powder does not seem to adversely affect the biocompatibility of titanium dental implant surfaces. However, the clinical impact of these findings requires further clarification.
本系统评价的目的是评估机械器械对钛牙种植体表面生物相容性的影响。
检索截至2013年12月的MEDLINE、Cochrane中心对照试验注册库和EMBASE数据库,以确定关于不同机械器械处理后,细胞在未污染和污染的、光滑和粗糙的钛表面上粘附和定植能力的对照研究。
全面检索共识别出1893篇潜在文献。11项研究符合纳入标准并被选入本评价。所有研究均为体外研究。大多数研究使用钛盘、钛条和钛柱。空气喷砂是最常评估的处理方式。现有研究具有高度异质性,无法对数据进行任何统计分析。因此,结论并非基于定量数据。器械处理似乎对不同细胞的附着有选择性影响。在存在污染的情况下,塑料刮匙、金属刮匙、旋转钛刷以及带有碳尖和抛光液的超声洁治系统似乎无法恢复粗糙钛表面的生物相容性。使用碳酸氢钠粉末的气粉喷砂系统在处理光滑或粗糙表面后,即使存在污染,似乎也不会影响成纤维细胞与钛表面的相互作用。
现有数据表明,使用碳酸氢钠粉末的气粉喷砂系统处理似乎不会对钛牙种植体表面的生物相容性产生不利影响。然而,这些发现的临床影响需要进一步阐明。