Abstract

A new cadmium (II) ion selective sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane (kryptofix5) as a supramolecular carrier has been developed. The membrane solutions containing polyvinyl chloride (PVC), plasticizer, sodium tetraphenylborate (NaTPB) as a lipophilic ionic additive and kryptofix5 as an ionophore were directly coated on the surface of graphite rods. The best composition of the coated membrane (w/w%) was found to be: 30.0% PVC, 61.0% dioctyl sebacate (DOS), 6.0% NaTPB and 3.0% kryptofix5. The sensor indicates a good linear response for Cd(2+) cation over a wide concentration range from 1.0×10(-5) to 1.0×10(-1) M with a Nernstian slope of 29.8±0.1 mV/decade and the detection limit is 8.4×10(-6) M. The response time of the sensor is 15s and it can be used for 7 weeks without significant drift in potential. The sensor operates in the wide pH range of 1.0-6.0. This sensor reveals a very good selectivity toward Cd(2+) ion over a wide range of alkali, transition and heavy metal cations. The sensor was used as an indicator electrode for potentiometric titration of Cd(2+) using sodium fluoride and ethylenediaminetetraacetic acid (EDTA) solutions with a sharp potential change that occurred at the end point. In addition, the proposed sensor was successfully used for determination of Cd(2+) cation in real water samples.

摘要

一种基于 1,13-双(8-喹啉基)-1,4,7,10,13-五氧杂环十五烷(kryptofix5)作为超分子载体的新型镉(II)离子选择性传感器已经被开发出来。含有聚氯乙烯(PVC)、增塑剂、四苯硼酸钠(NaTPB)作为亲脂性离子添加剂和 kryptofix5 作为离子载体的膜溶液直接涂覆在石墨棒的表面。发现涂层膜的最佳组成(w/w%)为:30.0% PVC、61.0%癸二酸二辛酯(DOS)、6.0% NaTPB 和 3.0% kryptofix5。该传感器对 Cd(2+)阳离子在 1.0×10(-5)到 1.0×10(-1) M 的宽浓度范围内表现出良好的线性响应,Nernst 斜率为 29.8±0.1 mV/decade,检测限为 8.4×10(-6) M。传感器的响应时间为 15s,在电位没有明显漂移的情况下可以使用 7 周。传感器在 1.0-6.0 的宽 pH 范围内工作。该传感器对 Cd(2+)离子表现出非常好的选择性,对广泛的碱、过渡和重金属阳离子都有很好的选择性。该传感器可作为指示电极,用于使用氟化钠和乙二胺四乙酸(EDTA)溶液进行 Cd(2+)的电位滴定,在终点时会发生明显的电位变化。此外,该传感器还成功地用于实际水样中 Cd(2+)阳离子的测定。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验