Because of the threat of bombings using improvised explosives containing ammonium nitrate (AN), law enforcement and intelligence communities have been interested in stable isotope techniques for tracking and discriminating AN sources. Separate analysis of the AN component ions ammonium and nitrate would add discriminatory power to these techniques.
Ammonium ions in dissolved AN solution were isolated from samples by precipitation using sodium tetraphenylborate solution. We tested the isolation of ammonium from nitrates using solutions of ammonium and nitrate salts with different (15)N/(14)N isotope ratios. Ammonium tetraphenylborate and AN were separately analyzed for their (15)N/(14)N isotope ratios using EA-ConFlo-IRMS, and the (15)N/(14)N isotope ratios of the nitrate ions were calculated using mass balance. Ammonium and nitrate nitrogen isotope ratios were plotted as two separate variables.
Isolation of ammonium precipitate from solutions containing dissolved nitrates did not influence the nitrogen isotope ratios of test ammonium salts. A survey set of 42 AN samples showed that the ammonium and nitrate (15)N/(14)N isotope ratios were not significantly correlated, and the paired mean differences were not statistically significant. Both ammonium and nitrate were depleted in (15)N relative to their theoretical atmospheric sources.
Isolation of the ammonium ion from AN adds another dimension for the discrimination of forensic AN samples. This technique using sodium tetraphenylborate is robust and does not require specialized equipment. Our observations indicated that ammonium nitrogen and nitrate nitrogen have independent sources of isotopic variation.
由于存在使用含硝酸铵(AN)的简易爆炸装置进行爆炸的威胁,执法和情报部门一直对用于追踪和鉴别硝酸铵来源的稳定同位素技术感兴趣。对硝酸铵成分离子铵和硝酸盐进行单独分析将增强这些技术的鉴别能力。
使用四苯硼酸钠溶液沉淀法从样品中分离溶解的硝酸铵溶液中的铵离子。我们使用具有不同(^{15}N/^{14}N)同位素比率的铵盐和硝酸盐溶液测试了从硝酸盐中分离铵的方法。使用EA-ConFlo-IRMS分别分析四苯硼酸铵和硝酸铵的(^{15}N/^{14}N)同位素比率,并使用质量平衡计算硝酸根离子的(^{15}N/^{14}N)同位素比率。将铵和硝酸盐氮同位素比率绘制成两个单独的变量。
从含有溶解硝酸盐的溶液中分离铵沉淀不会影响测试铵盐的氮同位素比率。一组42个硝酸铵样品的调查显示,铵和硝酸盐的(^{15}N/^{14}N)同位素比率没有显著相关性,配对平均差异也没有统计学意义。相对于其理论大气来源,铵和硝酸盐的(^{15}N)均有所贫化。
从硝酸铵中分离铵离子为法医硝酸铵样品的鉴别增加了另一个维度。这种使用四苯硼酸钠的技术很可靠,不需要专门设备。我们的观察表明,铵态氮和硝态氮有独立的同位素变化来源。