Suppr超能文献

牙齿颜色和不锈钢根管桩固位的比较评价:一项体外研究。

A Comparative Evaluation of the Retention of Tooth Coloured and Stainless Steel Endodontic Posts: An In-vitro Study.

作者信息

Keswani Kiran, Maria Rahul, Punga Rohit

机构信息

Reader, Department of Conservative Dentistry and Endodontics, Vyas Dental College and Hospital , Jodhpur, Rajasthan, India .

Head of the Department, Department of Conservative Dentistry and Endodontics, RishiRaj College of Dental Sciences , Bhopal, Madhya Pradesh, India .

出版信息

J Clin Diagn Res. 2014 Apr;8(4):ZC04-6. doi: 10.7860/JCDR/2014/7241.4220. Epub 2014 Apr 15.

Abstract

AIMS

This in vitro study evaluated: a) the retention of stainless steel posts of 1.5 mm diameter which were cemented with Zinc Phosphate cement versus Glass fiber posts with 1.1 mm, 1.3 mm and 1.5 mm diameters which were cemented with resin cement and b) the effect of change in diameter on the retention of Glass fiber posts with 1.1 mm, 1.3 mm and 1.5 mm diameters.

MATERIALS AND METHODS

Sixty extracted mandibular premolar teeth were endodontically treated and randomly assigned to four groups of fifteen teeth each. In Groups I, II and III glass fibre posts with diameters 1.1 mm, 1.3 mm and 1.5 mm were cemented by using resin cement. In Group IV, stainless steel posts with diameter 1.5 mm were cemented by using zinc phosphate cement. The specimens were tested for tensile loading at a cross head speed of 2.0 mm/min, on a universal testing machine.

STATISTICAL ANALYSIS USED

One way analysis of variance and Tukey's (post-hoc) test.

RESULTS

Mean tensile strength from highest to lowest was in the order of Group IV, Group II, Group III, Group I. Statistically significant differences were observed between the mean tensile strengths between Groups I and II, Groups I and III, Groups I and IV, Groups II and IV, Groups III and IV, while non significant differences were observed between Groups II and III.

CONCLUSION

Stainless steel posts were more retentive than glass fibre posts. Glass fibre posts with 1.3 mm or 1.5 mm diameters provided significantly greater retention as compared to 1.1 mm diameter posts.

摘要

目的

本体外研究评估了:a)用磷酸锌水门汀粘结的直径1.5mm不锈钢桩与用树脂水门汀粘结的直径1.1mm、1.3mm和1.5mm玻璃纤维桩的固位情况;b)直径变化对直径1.1mm、1.3mm和1.5mm玻璃纤维桩固位的影响。

材料与方法

60颗拔除的下颌前磨牙经根管治疗后随机分为四组,每组15颗牙。第一组、第二组和第三组分别用树脂水门汀粘结直径1.1mm、1.3mm和1.5mm的玻璃纤维桩。第四组用磷酸锌水门汀粘结直径1.5mm的不锈钢桩。在万能试验机上以2.0mm/min的十字头速度对标本进行拉伸加载测试。

所用统计分析方法

单因素方差分析和Tukey事后检验。

结果

平均拉伸强度从高到低依次为第四组、第二组、第三组、第一组。第一组与第二组、第一组与第三组、第一组与第四组、第二组与第四组、第三组与第四组之间的平均拉伸强度存在统计学显著差异,而第二组与第三组之间无显著差异。

结论

不锈钢桩的固位力比玻璃纤维桩更强。与直径1.1mm的玻璃纤维桩相比,直径1.3mm或1.5mm的玻璃纤维桩固位力显著更强。

相似文献

1
A Comparative Evaluation of the Retention of Tooth Coloured and Stainless Steel Endodontic Posts: An In-vitro Study.
J Clin Diagn Res. 2014 Apr;8(4):ZC04-6. doi: 10.7860/JCDR/2014/7241.4220. Epub 2014 Apr 15.
2
In vitro evaluation of the retention of composite fiber and stainless steel posts.
J Prosthodont. 2002 Mar;11(1):25-9. doi: 10.1111/j.1532-849x.2002.00025.x.
5
Retention of posts with resin, glass ionomer and hybrid cements.
J Dent. 1998 Sep;26(7):599-602. doi: 10.1016/s0300-5712(97)00043-2.
6
In vitro evaluation of the retention of zirconia-based ceramic posts luted with glass ionomer and resin cements.
Braz Dent J. 2005;16(3):213-7. doi: 10.1590/s0103-64402005000300008. Epub 2006 Jan 12.
8
Comparative evaluation of retention of prefabricated and conventional cast post: An in vitro study.
J Int Soc Prev Community Dent. 2014 May;4(2):87-91. doi: 10.4103/2231-0762.137635.
9
Effect of eugenol-based endodontic sealer on the adhesion of intraradicular posts cemented after different periods.
J Appl Oral Sci. 2009 Nov-Dec;17(6):579-83. doi: 10.1590/s1678-77572009000600008.
10
Assessment of Various Post Systems' Fracture Resistance after Endodontic Treatment.
J Pharm Bioallied Sci. 2024 Feb;16(Suppl 1):S699-S701. doi: 10.4103/jpbs.jpbs_949_23. Epub 2024 Feb 29.

本文引用的文献

1
An ex vivo comparative study on the retention of custom and prefabricated posts.
J Conserv Dent. 2012 Apr;15(2):183-6. doi: 10.4103/0972-0707.94583.
2
Effect of relining on fiber post retention to root canal.
J Appl Oral Sci. 2009 Nov-Dec;17(6):600-4. doi: 10.1590/s1678-77572009000600012.
3
A comparison of the retention of three endodontic dowel systems following different surface treatments.
J Prosthodont. 2008 Jun;17(4):269-73. doi: 10.1111/j.1532-849X.2007.00275.x. Epub 2007 Dec 17.
5
Influence of prefabricated post dimensions on restored maxillary central incisors.
J Oral Rehabil. 2007 Feb;34(2):141-52. doi: 10.1111/j.1365-2842.2006.01720.x.
6
Effects of luting agent and thermocycling on bond strengths to root canal dentine.
Int Endod J. 2006 Oct;39(10):809-18. doi: 10.1111/j.1365-2591.2006.01155.x.
8
In vivo fluid movement through dentin adhesives in endodontically treated teeth.
J Dent Res. 2005 Mar;84(3):223-7. doi: 10.1177/154405910508400303.
9
Various conditioning methods for root canals influencing the tensile strength of titanium posts.
J Oral Rehabil. 2004 Sep;31(9):890-4. doi: 10.1111/j.1365-2842.2004.01372.x.
10
The retentive effects of pre-fabricated posts by luting cements.
J Oral Rehabil. 2004 Jun;31(6):585-9. doi: 10.1111/j.1365-2842.2004.01276.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验