Suppr超能文献

Stent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era.

作者信息

Taherioun Mehrdad, Namazi Mohammad Hassan, Safi Morteza, Saadat Habibolah, Vakili Hossein, Alipour-Parsa Saeed, Rajabi-Moghadam Hasan, Pedari Shamsedin

机构信息

Cardiac Rehabilitation Research Centre, Isfahan Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.

Associate Professor, Cardiovascular Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

出版信息

ARYA Atheroscler. 2014 Jan;10(1):13-7.

Abstract

BACKGROUND

Stent underexpansion is the most powerful predictor of long-term stent patency and clinical outcome. The purpose of this study was to evaluate the incidence and predictors of stent underexpansion despite adjunctive post-dilatation with non-compliant balloon.

METHODS

After elective coronary stent implantation and adjunctive post-dilatation with non-compliant balloon and optimal angiographic result confirmed by the operator, intravascular ultrasound (IVUS) was performed for all the treated lesions. If the treated lesions fulfilled the IVUS criteria, they are considered as the optimal stent group; if not, they are considered as the suboptimal group.

RESULTS

From 50 patients enrolled in this study 39 (78%) had optimal stent deployment and 11 (22%) had suboptimal stent deployment. In the suboptimal group 7 (14%) had underexpansion, 2 (4%) malposition, and 2 (4%) had asymmetry. There were no stent edge dissections detected by IVUS. We did not find any correlation between lesion calcification, ostial lesions, stent length, and stent underexpansion. Stent diameter ≤ 2.75 mm had a strong correlation with stent underexpansion.

CONCLUSION

Despite adjunctive post-dilatation with noncompliant balloon, using a relatively small stent diameter was a strong predictor for underexpansion. IVUS guided percutaneous coronary intervention (PCI) may be considered for drug eluting stent (DES) implantation in relatively small vessels.

摘要

相似文献

2
IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled.
Curr Cardiol Rev. 2009 May;5(2):78-86. doi: 10.2174/157340309788166697.
7
Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study.
Catheter Cardiovasc Interv. 2009 Aug 1;74(2):348-56. doi: 10.1002/ccd.21973.
8
Prediction of Coronary Stent Underexpansion by Pre-Procedural Intravascular Ultrasound-Based Deep Learning.
JACC Cardiovasc Interv. 2021 May 10;14(9):1021-1029. doi: 10.1016/j.jcin.2021.01.033. Epub 2021 Apr 14.
9
Stent length is a contributing factor of suboptimal stent expansion in drug-eluting stents.
Kardiol Pol. 2015;73(8):598-605. doi: 10.5603/KP.a2015.0034. Epub 2015 Mar 3.

本文引用的文献

3
Intravascular ultrasound assessment of drug-eluting stent expansion.
Am Heart J. 2007 Feb;153(2):297-303. doi: 10.1016/j.ahj.2006.08.026.
5
A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.
N Engl J Med. 2004 Jan 15;350(3):221-31. doi: 10.1056/NEJMoa032441.
6
Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery.
N Engl J Med. 2003 Oct 2;349(14):1315-23. doi: 10.1056/NEJMoa035071.
9
Stent deployment in calcified lesions: can we overcome calcific restraint with high-pressure balloon inflations?
Catheter Cardiovasc Interv. 2001 Feb;52(2):164-72. doi: 10.1002/1522-726x(200102)52:2<164::aid-ccd1041>3.0.co;2-s.
10
Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study.
Circulation. 2000 Aug 1;102(5):523-30. doi: 10.1161/01.cir.102.5.523.