Suppr超能文献

根据西門氏方法行掌侧入路的近端指间关节成形术:8年随访结果

The palmar approach for PIP-arthroplasty according to Simmen: results after 8 years follow-up.

作者信息

Lautenbach Martin, Kim Simon, Berndsen Michael, Eisenschenk Andreas

机构信息

Department for the Upper Extremity, Hand-, and Microsurgery, Immanuel Krankenhaus, Königstr. 63, 14109, Berlin, Germany.

出版信息

J Orthop Sci. 2014 Sep;19(5):722-8. doi: 10.1007/s00776-014-0605-4. Epub 2014 Aug 12.

Abstract

BACKGROUND

Alloarthroplasty of the proximal interphalangeal joint is indicated for patients with osteoarthritis, an inflammatory disease of the joint. According to the current literature, implants made of silicone are not inferior to newer implants and the complications are well known. Therefore, focus should be shifted to the operative approach to improve the results.

METHODS

Eleven silicone arthroplasties in 7 patients with arthritis and 35 silicone arthroplasties in 23 patients with osteoarthritis were reviewed after 15.6 months and after 105.3 months. All implants were inserted using the palmar approach according to Simmen. We compared the pre- and postoperative arc of motion, pain, and strength, and present postoperative complications and satisfaction.

RESULTS

Patients with arthritis showed a gain in range of motion of 36° and patients with osteoarthritis of 39°. No implant failure occurred, and one revision was performed,. Average extension lag over all operated joints of patients was 2.8°. No swan-neck deformity or extensor tendon adhesion was observed. There was no significant difference in the postoperative results between patients with osteoarthritis and arthritis or between first and second follow-up.

CONCLUSION

Silicone arthroplasty restores the functionality of proximal interphalangeal joints in patients with osteoarthritis and inflammatory joint disease. Using a palmar approach, the surgeon can reach palmar and dorsal osteophytes. The extensor mechanism stays intact reducing the risk for extensor lag and other complications compared to the dorsal approach. The results do not change significantly between 1 and 8 years postoperatively.

摘要

背景

近端指间关节置换术适用于骨关节炎患者,这是一种关节炎症性疾病。根据当前文献,硅胶制成的植入物并不逊于新型植入物,且并发症众所周知。因此,应将重点转移到手术入路以改善治疗效果。

方法

对7例关节炎患者的11例硅胶关节置换术以及23例骨关节炎患者的35例硅胶关节置换术在术后15.6个月和105.3个月进行了回顾。所有植入物均按照西姆门的方法采用掌侧入路插入。我们比较了术前和术后的活动弧度、疼痛和力量,并呈现了术后并发症和满意度。

结果

关节炎患者的活动范围增加了36°,骨关节炎患者增加了39°。未发生植入物失败情况,仅进行了一次翻修手术。患者所有手术关节的平均伸展滞后为2.8°。未观察到鹅颈畸形或伸肌腱粘连。骨关节炎患者和关节炎患者之间或首次和第二次随访之间的术后结果无显著差异。

结论

硅胶关节置换术可恢复骨关节炎和炎症性关节疾病患者近端指间关节的功能。采用掌侧入路,外科医生能够触及掌侧和背侧骨赘。与背侧入路相比,伸肌机制保持完整,降低了伸展滞后和其他并发症的风险。术后1至8年结果无显著变化。