Abstract

The purpose of this study is intended to investigate the implementation of a modified class solution for intact prostate intensity-modulated radiation therapy (IMRT). The class solution uses 2 additional optimization structures intended to increase target conformity and decrease unnecessary dose to healthy tissue. A total of 10 randomly selected intact prostate IMRT patients were chosen for this retrospective study. Each of the original IMRT plans was compared with a modified class solution. The class solution implemented 2 additional optimization structures. The 95_OPT was intended to increase target conformity, and the Avoidance_3780 was intended to reduce normal tissue. Each plan was evaluated for minimum, maximum, and mean doses to the target. Additionally, mean normal tissue dose, total monitor units (MUs), and segments were investigated. Conformity index and normal healthy index were also compared. All comparisons were evaluated using a paired t-test using GraphPad software. Evaluations of MUs; segments; minimum, maximum, mean target doses; mean normal tissue dose; and conformity index did not demonstrate a significant difference between the modified class solution and the original plans. However, evaluation of healthy tissue conformity index indicated a significant difference. Overall, 70% of the original plans failed to demonstrate a satisfactory score (< 0.6) of properly sparing normal healthy tissue, whereas 70% of the modified plans exhibited a satisfactory score (> 0.6). Most (90%) of the modified plans demonstrated a greater number of segments than the compared original plan. A modified class solution provides a good starting point for planning intact prostate cancer. The addition of the Avoidance_3780 structure increases the healthy tissue conformity index score.

摘要

本研究旨在探讨一种改良的类解决方案在完整前列腺调强放射治疗(IMRT)中的应用。该类解决方案使用了另外两个优化结构,旨在提高靶区适形性并减少对健康组织的不必要剂量。本回顾性研究共随机选取了10例完整前列腺IMRT患者。将每个原始IMRT计划与改良的类解决方案进行比较。该类解决方案实施了另外两个优化结构。95_OPT旨在提高靶区适形性,而Avoidance_3780旨在减少正常组织受量。对每个计划的靶区最小、最大和平均剂量进行评估。此外,还研究了平均正常组织剂量、总监测单位(MUs)和射野分段数。比较了适形指数和正常健康指数。所有比较均使用GraphPad软件进行配对t检验评估。对MUs、射野分段数、靶区最小、最大、平均剂量、平均正常组织剂量和适形指数的评估未显示改良类解决方案与原始计划之间存在显著差异。然而,对健康组织适形指数的评估显示存在显著差异。总体而言,70%的原始计划未能显示出对正常健康组织进行适当保护的满意分数(<0.6),而70%的改良计划表现出满意分数(>0.6)。大多数(90%)改良计划的射野分段数比与之比较的原始计划更多。改良的类解决方案为完整前列腺癌的计划制定提供了一个良好的起点。Avoidance_3780结构的添加提高了健康组织适形指数分数。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验