Suppr超能文献

小儿患者的声辐射力脉冲成像:肝脏正常数值

Acoustic radiation force impulse imaging in paediatric patients: normal liver values.

作者信息

Matos Hugo, Trindade Ana, Noruegas Maria J

机构信息

*Pediatric Hospital, Medical Imaging Department and Faculty of Medicine, University Hospital of Coimbra, Coimbra †Science and Technology Faculty, University Nova of Lisbon, Lisbon, Portugal.

出版信息

J Pediatr Gastroenterol Nutr. 2014 Dec;59(6):684-8. doi: 10.1097/MPG.0000000000000539.

Abstract

OBJECTIVES

The objective of this study was to obtain a normal value for liver shear wave velocities (SWVs) in healthy paediatric patients and to investigate variations concerning age, sex, and different approaches, depths, and lobes of measurements.

METHODS

A total of 150 healthy children (2 months-17 years) were examined with acoustic radiation force impulse (ARFI) technology by an experienced paediatric radiologist, after receiving an informed consent. Measurements obtained were divided according to group age (n = 50, 0-5 years; n = 50, 6-11 years; n = 50, 12-17 years); sex (male-female); lobe (right-left lobe); approach (intercostal-subcostal), and depth of measurements (1-5 and 5-6 cm for the youngest group; 2-6 to 6-8 cm for the 2 other groups). Comparative analyses were performed with measurements obtained at right and left lobes, with different depths and approaches. Differences between age and sex were also analysed.

RESULTS

Mean SWV in the right liver lobe was 1.07 ± 0.10 m/s. No significant differences were found according to sex or among different probe locations. SWVs were, however, significantly higher within left lobe in comparison with right liver lobe (1.07 ± 0.10 m/s, right; 1.21 ± 0.16 m/s, left). Depth of measurements also influenced SWV values obtained, being slightly lower at deeper locations. Regarding the age significant differences were found for children <6 years old compared with other age groups.

CONCLUSIONS

ARFI analysis seems to be influenced by age, depth, and lobe of measurements. A mean SWV value of 1.07 ± 0.10 m/s for healthy paediatric population with the possibility of reaching 1.12 m/s in the case of younger children was found. ARFI values were more consistently obtained analysing right liver lobe and depths lower than 5 to 6 cm.

摘要

目的

本研究的目的是获取健康儿科患者肝脏剪切波速度(SWV)的正常值,并研究其在年龄、性别以及不同测量方法、深度和肝叶方面的差异。

方法

在获得知情同意后,由一位经验丰富的儿科放射科医生使用声辐射力脉冲(ARFI)技术对总共150名健康儿童(2个月至17岁)进行检查。所获得的测量值根据年龄组(n = 50,0至5岁;n = 50,6至11岁;n = 50,12至17岁)、性别(男-女)、肝叶(右叶-左叶)、测量方法(肋间-肋下)以及测量深度(最年幼组为1至5厘米和5至6厘米;其他两组为2至6厘米至6至8厘米)进行划分。对在右叶和左叶、不同深度和测量方法下获得的测量值进行比较分析。还分析了年龄和性别的差异。

结果

右肝叶的平均SWV为1.07±0.10米/秒。根据性别或不同探头位置未发现显著差异。然而,左叶的SWV明显高于右肝叶(右叶为1.07±0.10米/秒,左叶为1.21±0.16米/秒)。测量深度也会影响所获得的SWV值,较深位置的值略低。在年龄方面,发现6岁以下儿童与其他年龄组存在显著差异。

结论

ARFI分析似乎受年龄、深度和测量肝叶的影响。发现健康儿科人群的平均SWV值为1.07±0.10米/秒,年幼儿童可能达到1.12米/秒。分析右肝叶和低于5至6厘米的深度时,ARFI值的获取更一致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验