Suppr超能文献

不同冷却方式对高温作用下水泥基复合材料力学性能的影响

Effect of different cooling regimes on the mechanical properties of cementitious composites subjected to high temperatures.

作者信息

Yu Jiangtao, Weng Wenfang, Yu Kequan

机构信息

College of Civil Engineering, Tongji University, Shanghai 200092, China.

出版信息

ScientificWorldJournal. 2014 Apr 9;2014:289213. doi: 10.1155/2014/289213. eCollection 2014.

Abstract

The influence of different cooling regimes (quenching in water and cooling in air) on the residual mechanical properties of engineered cementitious composite (ECC) subjected to high temperature up to 800°C was discussed in this paper. The ECC specimens are exposed to 100, 200, 400, 600, and 800°C with the unheated specimens for reference. Different cooling regimens had a significant influence on the mechanical properties of postfire ECC specimens. The microstructural characterization was examined before and after exposure to fire deterioration by using scanning electron microscopy (SEM). Results from the microtest well explained the mechanical properties variation of postfire specimens.

摘要

本文讨论了不同冷却方式(水淬和空冷)对工程水泥基复合材料(ECC)在高达800°C高温下残余力学性能的影响。将ECC试件分别暴露于100、200、400、600和800°C温度下,并设置未加热试件作为参照。不同的冷却方式对火灾后ECC试件的力学性能有显著影响。通过扫描电子显微镜(SEM)对火灾劣化前后的微观结构特征进行了研究。微观测试结果很好地解释了火灾后试件力学性能的变化。