Tchantchaleishvili Vakhtang, Melvin Amber L, Ling Frederick S, Knight Peter A
Division of Cardiac Surgery, University of Rochester Medical Center, Rochester, USA
Division of Cardiac Surgery, University of Rochester Medical Center, Rochester, USA.
Interact Cardiovasc Thorac Surg. 2014 Dec;19(6):1074-6. doi: 10.1093/icvts/ivu271. Epub 2014 Sep 1.
Transcatheter device closure of atrial septal defects (ASDs) is a minimally invasive technique that offers an alternative to conventional surgical repair. There are risks imposed by this technique; however, they compare favourably with risks of surgical closure. Here, we present a case of a 59-year old male with late erosion of an Amplatzer septal occluder device resulting in cardiac tamponade 5 years after device placement. To the best of our knowledge, cardiac tamponade this late after device placement has not yet been reported. Septal occlusion device erosion remains a major issue among the risks imposed by device closure of an ASD. More data are needed to better understand its true causes and possible solutions.
经导管装置封堵房间隔缺损(ASD)是一种微创技术,为传统外科修复提供了一种替代方案。该技术存在风险;然而,与外科封堵的风险相比,这些风险具有优势。在此,我们报告一例59岁男性病例,其在放置Amplatzer房间隔封堵器装置5年后出现晚期侵蚀,导致心脏压塞。据我们所知,装置放置后如此晚期出现心脏压塞尚未见报道。在ASD装置封堵所带来的风险中,间隔封堵器侵蚀仍然是一个主要问题。需要更多数据来更好地了解其真正原因和可能的解决方案。