采用四种不同的分光光度法对佐匹克隆及其杂质进行定量测定。

Quantitative determination of zopiclone and its impurity by four different spectrophotometric methods.

作者信息

Abdelrahman Maha M, Naguib Ibrahim A, El Ghobashy Mohamed R, Ali Nesma A

机构信息

Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University, Alshaheed Shehata Ahmad Hegazy St., 62514 Beni-Suef, Egypt.

Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini St., 11562 Cairo, Egypt.

出版信息

Spectrochim Acta A Mol Biomol Spectrosc. 2015 Feb 25;137:617-24. doi: 10.1016/j.saa.2014.08.071. Epub 2014 Sep 4.

Abstract

Four simple, sensitive and selective spectrophotometric methods are presented for determination of Zopiclone (ZPC) and its impurity, one of its degradation products, namely; 2-amino-5-chloropyridine (ACP). Method A is a dual wavelength spectrophotometry; where two wavelengths (252 and 301 nm for ZPC, and 238 and 261 nm for ACP) were selected for each component in such a way that difference in absorbance is zero for the second one. Method B is isoabsorptive ratio method by combining the isoabsorptive point (259.8 nm) in the ratio spectrum using ACP as a divisor and the ratio difference for a single step determination of both components. Method C is third derivative (D(3)) spectrophotometric method which allows determination of both ZPC at 283.6 nm and ACP at 251.6 nm without interference of each other. Method D is based on measuring the peak amplitude of the first derivative of the ratio spectra (DD(1)) at 263.2 nm for ZPC and 252 nm for ACP. The suggested methods were validated according to ICH guidelines and can be applied for routine analysis in quality control laboratories. Statistical analysis of the results obtained from the proposed methods and those obtained from the reported method has been carried out revealing high accuracy and good precision.

摘要

本文提出了四种简单、灵敏且具选择性的分光光度法,用于测定佐匹克隆(ZPC)及其杂质(其降解产物之一,即2-氨基-5-氯吡啶(ACP))。方法A为双波长分光光度法;为每种组分选择了两个波长(ZPC为252和301nm,ACP为238和261nm),使得第二个组分的吸光度差值为零。方法B是等吸收比法,通过将以ACP为除数的比率光谱中的等吸收点(259.8nm)与比率差值相结合,对两种组分进行单步测定。方法C是三阶导数(D(3))分光光度法,可在283.6nm处测定ZPC,在251.6nm处测定ACP,且互不干扰。方法D基于测量比率光谱一阶导数(DD(1))在263.2nm(针对ZPC)和252nm(针对ACP)处的峰高。所建议的方法已按照国际人用药品注册技术协调会(ICH)指南进行了验证,可应用于质量控制实验室的常规分析。对所提出方法和已报道方法所得结果进行的统计分析表明,该方法具有高准确性和良好精密度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验