J Clin Anesth. 2014 Dec;26(8):587-90. doi: 10.1016/j.jclinane.2014.04.004. Epub 2014 Sep 27.
To confirm the relationship between bevel orientation, catheter direction, and radiopaque contrast spread in the lumbar region.
Pilot cadaver study.
Anatomy laboratory of a university hospital.
Cadavers were randomized to two groups of 4 cadavers each. In Group 1, needle bevel direction at epidural entry was cephalad; in Group 2, it was caudad. After placement of each epidural catheter in L4-L5 interspace, 2 mL of radiopaque contrast was injected and a lumbar posterior-anterior radiograph was obtained. Catheter direction and direction of radiopaque contrast spread were collected.
Due to the inability to access the epidural space secondary to surgical changes in the lumbar spine, one cadaver in the cephalad group was excluded. In 7 of 7 (100%) cadavers, the catheter tip direction according to the radiograph corresponded directly with bevel direction.
A strong relationship exists between bevel orientation and catheter direction; however, catheter position does not reliably predict the direction in which the injected fluid spreads in all cadavers.