Ghoreishi Mohammad, Agherian Reihane, Peyman Ali Reza, Feshareki Hamid, Mohammadinia Mohadeseh
Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran.
J Ophthalmic Vis Res. 2014 Apr;9(2):174-80.
To assess the visual and refractive outcomes of flexible toric iris claw phakic intraocular lens implantation for correction of moderate to high myopia with astigmatism.
In this non-randomized prospective study, 31 eyes of 18 patients including 8 male and 10 female subjects with mean age of 27.62±5.53 (range 19 to 38) years with moderate to high myopia and astigmatism underwent toric Artiflex (Ophtec BV, Groningen, Netherlands) phakic intraocular lens (PIOL) implantation. Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were measured in logarithm of minimum angle of resolution (logMAR) notations. Manifest refraction, safety, efficacy, predictability and complications were measured 6 months after surgery.
Pre-operatively, mean spherical equivalent (SE) refractive error was -9.68±1.92 (range -14.00 to -6.00) diopter (D) and mean cylinder was -2.79±1.06 (range -4.75 to -1.00) D. After a minimum of 6 months, mean SE was -0.38±0.27 (range -0.87 to 0.00) D and mean cylinder was -0.66±0.43 (range -1.50 to 0.00) D. SE was within 0.50 D of emmetropia in 63.8% and within 1.0 D of target refraction in 100% of eyes. UDVA was equal or better than 20/20 in 45.1% of eyes while CDVA was equal or better than 20/20 in 67.7%; 83.8% of eyes gained 1 or more Snellen lines of CDVA after surgery. No serious complications occurred in this series of cases.
Implantation of the toric Artiflex PIOL is a safe and effective procedure for correction of moderate to high myopia with astigmatism.
评估可弯曲的有晶状体眼散光型虹膜爪状人工晶状体植入术矫正中高度近视合并散光的视觉和屈光效果。
在这项非随机前瞻性研究中,18例患者(8例男性和10例女性)的31只眼,平均年龄为27.62±5.53岁(范围19至38岁),患有中高度近视和散光,接受了Artiflex(荷兰格罗宁根Ophtec BV公司)有晶状体眼人工晶状体(PIOL)植入术。以最小分辨角对数(logMAR)记录法测量未矫正远视力(UDVA)和矫正远视力(CDVA)。在术后6个月测量显验光、安全性、有效性、可预测性和并发症情况。
术前,平均等效球镜(SE)屈光不正为-9.68±1.92(范围-14.00至-6.00)屈光度(D),平均柱镜为-2.79±1.06(范围-4.75至-1.00)D。至少6个月后,平均SE为-0.38±0.27(范围-0.87至0.00)D,平均柱镜为-0.66±0.43(范围-1.50至0.