Standards for echocardiographic laboratories were proposed by the European Association of Echocardiography (now the European Association of Cardiovascular Imaging) 7 years ago, to raise standards of practice and improve the quality of care. Criteria and requirements were published at that time for transthoracic, transoesophageal, and stress echocardiography. This paper reassesses and updates the quality standards to take account of experience and the technical developments of modern echocardiographic practice. It also discusses quality control, the incentives for laboratories to apply for accreditation, the re-accreditation criteria, and the current status and future prospects of the laboratory accreditation process.
七年前,欧洲超声心动图协会(现为欧洲心血管影像协会)提出了超声心动图实验室标准,以提高实践标准并改善护理质量。当时发布了经胸、经食管和负荷超声心动图的标准和要求。本文重新评估并更新了质量标准,以考虑现代超声心动图实践的经验和技术发展。它还讨论了质量控制、实验室申请认证的激励措施、重新认证标准以及实验室认证过程的现状和未来前景。