While simultaneous acquisition of electrocardiography (ECG) data during MRI is a widely used clinical technique, the effects of the MRI environment on impedance cardiography (ICG) data have not been characterized. We collected echo planar MRI scans while simultaneously recording ECG and thoracic impedance using carbon fiber electrodes and customized amplifiers. Here, we show that the key changes in impedance (dZ/dt) and features of the ECG waveforms are not obstructed during MRI. We present a method for ensemble averaging ICG/ECG signals collected during MRI and show that it performs comparably with signals collected outside the MRI environment. These results indicate that ICG can be used during MRI to measure stroke volume, cardiac output, preejection period, and left ventricular ejection time.

摘要

虽然在磁共振成像(MRI)期间同步采集心电图(ECG)数据是一种广泛应用的临床技术,但MRI环境对阻抗心动图(ICG)数据的影响尚未得到明确描述。我们在使用碳纤维电极和定制放大器同步记录ECG和胸阻抗的同时,收集了回波平面MRI扫描数据。在此,我们表明在MRI期间,阻抗的关键变化(dZ/dt)和ECG波形特征并未受到阻碍。我们提出了一种对MRI期间采集的ICG/ECG信号进行总体平均的方法,并表明其性能与在MRI环境外采集的信号相当。这些结果表明,ICG可在MRI期间用于测量每搏输出量、心输出量、射血前期和左心室射血时间。